Page History
...
Affected Product | Replacement |
---|---|
TE0720-03-2IFC5 | TE0720-04-62I33MA |
TE0720-03-2IFC7 | TE0720-04-62I33MA |
TE0720-03-1CFC1 | TE0720-04-61C33MA |
TE0720-03-1QC9 | TE0720-04-61Q33MA |
TE0720-03-2IFC9 | TE0720-04-62I33MA |
TE0720-03-L1IFN | TE0720-04-64I63MA |
TE0720-03-1QC10 | TE0720-04-61Q33MA |
TE0720-03-1QFC | TE0720-04-61Q33MA |
TE0720-03-1CRV1 | TE0720-04-61C530A |
TE0720-03-1CRV2 | TE0720-04-61C530A |
TE0720-03-62I120M | TE0720-04-62I120M |
TE0720-03-62I32-V1 | TE0720-04-62I33-V1 |
TE0720-03-1QFC1 | TE0720-04-61Q33MA |
TE0720-03-62I330M | TE0720-04-62I330M |
TE0720-03-61C530A | TE0720-04-61C530A |
TE0720-03-61Q43GA | TE0720-04-61Q43GA |
TE0720-03-61Q86KL | TE0720-04-61Q86KL |
TE0720-03-61C530AS | TE0720-04-61C530AS |
TE0720-03-31C33MA | TE0720-04-31C33MA |
TE0720-03-61C33MA | TE0720-04-61C33MA |
TE0720-03-61Q33MA | TE0720-04-61Q33MA |
TE0720-03-61C33MAS | TE0720-04-61C33MAS |
TE0720-03-S005 | TE0720-04-S005 |
TE0720-03-S006C1 | TE0720-04-S006C1 |
TE0720-03-S007C1 | TE0720-04-S007C1 |
TE0720-03-S008C1 | TE0720-04-S008C1 |
TE0720-03-S009C1 | TE0720-04-S009C1 |
TE0720-03-61Q33ML | TE0720-04-61Q33ML |
TE0720-03-62I33MA | TE0720-04-62I33MA |
TE0720-03-62I33MAN | TE0720-04-62I33MAN |
TE0720-03-62I33ML | TE0720-04-62I33ML |
TE0720-03-64I63MA | TE0720-04-64I63MA |
TE0720-03-S003C1 | TE0720-04-S003C1 |
TE0720-03-62I12NA | TE0720-04-62I12NA |
TE0720-03-62I33NA | TE0720-04-62I33GA |
TE0720-03-61Q42NA | TE0720-04-61Q42NA |
TE0720-03-S010 | TE0720-04-S010 |
TE0720-03-S025C1 | TE0720-04-S025C1 |
Changes
...
#1 Auxiliary information has been added on Samtec B2B connectors page.
Type: DOC Change
Reason: Improve connector documentation.
Impact: None.
...
#2 Added legal notices.
Type: DOC Change
Reason: Clarify copyright issues.
Impact: None. Schematic page number changes.
...
#3 Added revision change history.
Type: DOC Change
Reason: Record revision changes.
Impact: None. Schematic page number changes.
...
#4 Added system overview.
Type: DOC Change
Reason: Display system information.
Impact: None. Schematic page number changes.
...
#5 Added power diagram.
Type: DOC Change
Reason: Display supply power information.
Impact: None. Schematic page number changes.
...
#6 Change power page.
Type: DOC Change
Reason: Improve power documentation.
Impact: None. Schematic page number changes.
...
#7 Replace EN6347QI (U1) by MPM3840GQV-Z
Type: Schematic Change
Reason: Enpirion DCDCs are discontinued.
Impact: None.
...
#8 Replace EP53F8QI (U2, U3) by MPM3834CGPA
Type: Schematic Change
Reason: Enpirion DCDCs are discontinued.
Impact: None. Maximum continuous output current of DCDC increased from 1.5 A to 3 A on each rail.
...
#9 Replace TPS27082LDDCR (Q1) by MP5077GG-Z
Type: Schematic Change
Reason: Part is EOL.
Impact: None.
...
#10 Replace BKP0603HS (L1, L2, L3, L4, L5, L7, L8) by MPZ0603S121HT000
Type: Schematic Change
Reason: Ferrid bead are discontinued.
Impact: None.
#11 Replace DCDC decoupling capacitor (1 uF 6.3 V)(C14) by capacitor (47 uF, 6.3 V) for FPGA decoupling
Type: Schematic Change
Reason: DCDC was changed and designator was used for the new capacitor.
Impact: None.
#12 Changed voltage divider resistors (R21, R61) to set the threshold for U26.
Type: Schematic Change
Reason: Set reset threshold for U26 to 0.904 V.
Impact: None.
#13 Added power supervisor BD39040MUF (U27)
Type: Schematic Change
Reason: Improve the voltage rail supervision.
Impact: None.
...
#14 Connect BD39040MUF "PG_All" - signal U27.15 to system controller U19.C12 with pull-up resistor R67.
Type: Schematic Change
Reason: Power Supervisor connection.
Impact: None.
...
#15 Connect BD39040MUF "WDEN" - signal U27.13 to system controller U19.C6 with pull-down resistor R80.
Type: Schematic Change
Reason: Power Supervisor connection.
Impact: None.
...
#16 Connect BD39040MUF "WDIN" - signal U27.14 to system controller U19.N8.
Type: Schematic Change
Reason: Power Supervisor connection.
Impact: None.
...
#17 Connect BD39040MUF "WDOUT" - signal U27.16 to system controller U19.M3.
Type: Schematic Change
Reason: Power Supervisor connection.
Impact: None.
...
#18 Signal MIO8 (U5.E5) connected to system controller (U19.N7).
Type: Schematic Change
Reason: Enable boundary scan for MIO bank 1.
Impact: None.
...
#19 Added pull-down resistors R64 for net "ON_1V0".
Type: Schematic Change
Reason: Default pull-down option to avoid floating states.
Impact: None.
...
#20 Added pull-down resistors R65 for net "ON_1V8".
Type: Schematic Change
Reason: Default pull-down option to avoid floating states.
Impact: None.
...
#21 Power supervisor U26 connected to 3.3VIN power rail (was 3.3V).
Type: Schematic Change
Reason: Avoid high-signal-state at U26 manual reset pin 3 without powered supervisor.
Impact: None.
...
#22 Added protection diode D3 to U26.3 (#MR input).
Type: Schematic Change
Reason: Avoid voltage high-signal-state at U26 manual reset pin 3 without powered supervisor.
Impact: None.
...
#23 Changed PCB layout of power supplies.
Type: PCB Change
Reason: DCDCs with new footprints needs to be used.
Impact: None.
...
#24 Added option to install Heatsink SuperGrip (c).
Type: PCB Change
Reason: Improve optional cooling solution.
Impact: None.
...
#25 Added capacitors C7 and C8 (100uF, 1V).
Type: PCB Change
Reason: Improve decoupling for "1V" voltage rail.
Impact: None.
...
#26 Changed PCB layout of Samtec B2B signals.
Type: PCB Change
Reason: Result of this PCN changes.
...