Reason: Set reset threshold for U26 to 0.904 V.
Impact: None., improved reset behaviour
#13 Added power supervisor BD39040MUF (U27)
Type: Schematic Change
Reason: Improve the Improved voltage rail supervision.
Impact: None. All power rails are now monitored.
#14 Connect BD39040MUF "PG_All" - signal U27.15 to system controller U19.C12 with pull-up resistor R67.
...
Reason: Power Supervisor connection.
Impact: None. Check your If custom CPLD design used, check for compatibility.
#15 Connect BD39040MUF watchdog to CPLD ("WDEN" - signal U27.13 to system controller U19.C6 with pull-down resistor R80
...
Type: Schematic Change
Reason: Power Supervisor connection.
Impact: None. Check your CPLD design for compatibility.
...
, "WDIN" - signal U27.14 to system controller U19.N8
...
Type: Schematic Change
Reason: Power Supervisor connection.
Impact: None. Check your CPLD design for compatibility.
...
, "WDOUT" - signal U27.16 to system controller U19.M3).
Type: Schematic Change
Reason: Power Supervisor connectionWatchDog connected for possible future use to CPLD.
Impact: None. Check your WatchDog connected for custom use to CPLD. If custom CPLD design used, check for compatibility.
#18 Signal MIO8 (U5.E5) connected to system controller (U19.N7).
...
Reason: Enable boundary scan for MIO bank 1.
Impact: None. Check your If custom CPLD design used, check for compatibility.
#19 Added pull-down resistors R64 for net "ON_1V0".
...
The model code and revision number of the module "TE0720-04" are printed on the top side of the PCB for revision 04.