Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Affected Product

Changes

Replacement
TE0813-01-2AE11-AZ#1...#16#19TE0813-02-2AE81-A
TE0813-01-4BE11-A#2...#16#19TE0813-02-4BE81-A
TE0813-01-4BE11-AZ#1...#16#19TE0813-02-4BE81-A
TE0813-01-4BE81-A#3..#16#19TE0813-02-4BE81-A
TE0813-01-4BE81-AZ#1, #3...#16#19TE0813-02-4BE81-A
TE0813-01-4DE11-A#2...#16#19TE0813-02-4DE81-A
TE0813-01-4DE11-AZ#1...#16#19TE0813-02-4DE81-A

(ED: Table with affected products should be final!)

...

Reason: Remote sense option.

Impact: None.

...

#15 Added additional decoupling capacitors C149...C157, C170...C172, C178, C187...C191, C195...C216.

Type: Schematic Change

Reason: Improve decoupling.

Impact: None.

...

#16 Added testpoints TP4, TP19, TP26.

Type: Schematic Change

Reason: Improve voltage measuring possibilities.

Impact: None.

...

#17 Added UKCA logo.

Type: PCB Change

Reason: Required for export to UK.

Impact: None.

...

#18 Changed 100 nF capacitors C135 and C136 from 6.3 V to 25 V.

Type: BOM Change

Reason: BOM Optimization.

Impact: None.

...

#19 Signal trace lengths changed

Type: PCB change

Reason: Result of changes above.

...