Page History
...
Affected Product | Changes | Replacement |
---|---|---|
TE0813-01-2AE11-AZ | #1...#16#19 | TE0813-02-2AE81-A |
TE0813-01-4BE11-A | #2...#16#19 | TE0813-02-4BE81-A |
TE0813-01-4BE11-AZ | #1...#16#19 | TE0813-02-4BE81-A |
TE0813-01-4BE81-A | #3..#16#19 | TE0813-02-4BE81-A |
TE0813-01-4BE81-AZ | #1, #3...#16#19 | TE0813-02-4BE81-A |
TE0813-01-4DE11-A | #2...#16#19 | TE0813-02-4DE81-A |
TE0813-01-4DE11-AZ | #1...#16#19 | TE0813-02-4DE81-A |
(ED: Table with affected products should be final!)
...
Reason: Remote sense option.
Impact: None.
...
#15 Added additional decoupling capacitors C149...C157, C170...C172, C178, C187...C191, C195...C216.
Type: Schematic Change
Reason: Improve decoupling.
Impact: None.
...
#16 Added testpoints TP4, TP19, TP26.
Type: Schematic Change
Reason: Improve voltage measuring possibilities.
Impact: None.
...
#17 Added UKCA logo.
Type: PCB Change
Reason: Required for export to UK.
Impact: None.
...
#18 Changed 100 nF capacitors C135 and C136 from 6.3 V to 25 V.
Type: BOM Change
Reason: BOM Optimization.
Impact: None.
...
#19 Signal trace lengths changed
Type: PCB change
Reason: Result of changes above.
...
Overview
Content Tools