CompanyTrenz Electronic GmbH
PCN NumberPCN-20230620
TitleTE0710-02 to TE0710-03 Hardware Revision Change
SubjectHardware Revision Change
Issue Date

2023-0710-01

Products Affected

This change affects all Trenz Electronic TE0710 SoMs: TE0710-02*.(ED: Check table!)

Affected Product

Changes

Replacement
TE0710-02-100-2CF#1...#16TE0710-03-72C21-A
TE0710-02-35-2CF#1...#16TE0710-03-42C21-A
TE0710-02-42I21-A#2...#16TE0710-03-42I21-A
TE0710-02-72I21-A#2...#16TE0710-03-72I21-A
TE0710-02-100-1Q#1...#16TE0710-03-71Q21-A (Artikel noch nicht erstellt????)

Changes

#1 Changed DDR3L SDRAM (U12) from

...

IM4G08D3FABG-125 to IS43TR85120BL-125KBLI.

...

Type: BOM change

Reason:  Old DDR was not specified for industrial temperature range.

Impact:

...

New timings may be considered for existing designs.

#2 Changed DCDC EN6347QI (U1) to MPM3860GQW-Z and adapted power circuit.

Type: Schematic Change

Reason: BOM OptimizationEOL of Component.

Impact: None. Increased current output capability. Minor changes in electrical characteristics.

#3 Changed

...

DCDC EN5311QI (U10, U11) to MPM3834CGPA and adapted power circuit.

Type: Schematic Change

Reason: EOL of Component.

Impact: None. Increased current output capability. Minor changes in electrical characteristics.

#4 Changed load switch from TPS27082LDDCR (Q1) to MP5077GG-Z and adapted circuit.

Type: Schematic Change

Reason: Use new clock revisionBOM Optimization.

Impact: None.

...

Increased current output capability. Minor changes in electrical characteristics.

#5 Changed power supervisor TPS3805H33DCKR (U23) to STM6710LWB6F and adapted circuits.

Type: Schematic Change

Reason: Improved power monitoring.

Impact: Improved power monitoring circuit by supervising additional voltage rails. If monitored voltages are out of range signal "PG_ALL" is triggered.

...

#6 Improved voltage rail VTT decoupling via adding capacitors C135...

...

C138.

Type: Schematic Change

Reason:  EOL of ComponentVTT decoupling improvement.

Impact: NoneImproved VTT voltage rail reliabililty.

...

#7 Changed

...

clock (

...

U9) from SiT8008AI-73-XXS-25.000000E to SiT8008BI-73-XXS-25.000000E.

Type: Schematic Change

Reason: EOL of ComponentUse new clock revision.

Impact: None. Increased current output capability. Minor changes in electrical characteristics.

...

#8 Changed ferrid bead BKP0603HS121-T (L1...L6) to MPZ0603S121HT000.

Type: Schematic Change

Reason: EOL of Component.

Impact: None. Increased current output capability. Minor changes in electrical characteristics.

...

#9 Added diode D4 between signal nets "INIT" and "PROG_B".

Type: Schematic Change

Reason: Keep FPGA in reset while signal "PROG_B" is low during initial power-up.

Impact: None.

...

#10 Added pull-up resistor R50 for signal net "PROG_B".

Type: Schematic Change

Reason: Remove floating signal situations and enable signal measurement.

Impact: None. Firmware reflects it but custom firmware needs to be updated by customer.

...

#11 Added testpoints TP1...

...

TP28.

Type: Schematic Change

Reason: Improve voltage measuring possibilities.

Impact: None.

...

#12 Changed size from 0805 to 0603 for capacitor C44.

Type: Schematic Change

Reason: BOM Optimization.

Impact: None.

...

#13 Changed fiducials to standard fiducial type.

Type: Schematic Change

Reason: Use standard fiducials.

Impact: None.

#14 Added UKCA logo.

Type: PCB Change

Reason: Required for export to UK.

Impact: None.

...

#15 Updated components from library.

Type: Schematic Change

Reason: Use latest component data.

Impact: None.

...

#16 Updated documentation on page "B2B_Connectors".

Type: Documentation Update

Reason: Documentation improvement.

Impact: None.

...

#17 Updated overview

...

Type: Documentation Update

Reason: Documentation improvement.

Impact: None.

#16 Updated power overview.

Type: Documentation Update

Reason: Documentation improvement.

Impact: None.

...

, power overview, revision history and legal notices.

Type: Documentation Update

Reason: Documentation improvement.

...