Page History
...
This change affects all Trenz Electronic TE0808 SoMs: TE0808-05*.
Affected Product | Changes | Intermediate Product 1) | Changes | Replacement |
---|---|---|---|---|
TE0808-05-6BE21-A | #1, #3 | - | - | TE0808-05-6BE81-E |
TE0808-05-6BE21-AK | #1, #3 | - | - | TE0808-05-6BE81-EK |
TE0808-05-6BE21-AZ | #1, #2, #3 | - | - | TE0808-05-6BE81-E |
TE0808-05-6BE21-L | #1 | TE0808-05-6BE21-F | #3 | TE0808-05-6BE81-F |
TE0808-05-6BE21-LK | #1, #3 | - | - | TE0808-05-6BE81-FK |
TE0808-05-6BE81-A | #1 | - | - | TE0808-05-6BE81-E |
TE0808-05-6BE81-AK | #1 | - | - | TE0808-05-6BE81-EK |
TE0808-05-6BE81-L | #1 | - | - | TE0808-05-6BE81-F |
TE0808-05-6BI21-X | #1 | - | - | S-Variant 2) |
TE0808-05-6BI41-X | #1 | - | - | S-Variant 2) |
TE0808-05-9BE21-A | #1 | TE0808-05-9BE21-E | #3 | TE0808-05-9BE81-E |
TE0808-05-9BE21-AK | #1, #3 | - | - | TE0808-05-9BE81-EK |
TE0808-05-9BE21-AS | #1, #3 | - | - | TE0808-05-9BE81-ES |
TE0808-05-9BE21-AZ | #1, #2, #3 | - | - | TE0808-05-9BE81-E |
TE0808-05-9BE21-KZ | #1, #2, #3 | - | - | TE0808-05-9BE81-EK |
TE0808-05-9BE21-L | #1 | TE0808-05-9BE21-F | #3 | TE0808-05-9BE81-F |
TE0808-05-9BE21-LK | #1, #3 | - | - | TE0808-05-9BE81-FK |
TE0808-05-9BE21-LZ | #1, #2, #3 | - | - | TE0808-05-9BE81-F |
TE0808-05-9BE81-A | #1 | - | - | TE0808-05-9BE81-E |
TE0808-05-9BE81-AK | #1 | - | - | TE0808-05-9BE81-EK |
TE0808-05-9BE81-AS | #1 | - | - | TE0808-05-9BE81-ES |
TE0808-05-9BI41-X | #1 | - | - | S-Variant 2) |
TE0808-05-9GI21-A | #1 | TE0808-05-9GI21-E | #3 | TE0808-05-9GI81-E |
TE0808-05-9GI21-AK | #1 | TE0808-05-9GI21-EK | #3 | TE0808-05-9GI81-EK |
TE0808-05-9GI21-AS | #1, #3 | - | - | TE0808-05-9GI81-ES |
TE0808-05-9GI21-AZ | #1, #2, #3 | - | - | TE0808-05-9GI81-E |
TE0808-05-9GI21-C | #1, #3 | - | - | TE0808-05-9GI81-C |
TE0808-05-9GI21-KZ | #1, #2, #3 | - | - | TE0808-05-9GI81-E |
TE0808-05-9GI81-A | #1 | - | - | TE0808-05-9GI81-E |
TE0808-05-9GI81-AK | #1 | - | - | TE0808-05-9GI81-EK |
TE0808-05-BBE21-A | #1 | TE0808-05-BBE21-E | #3 | TE0808-05-BBE81-E |
TE0808-05-BBE21-AK | #1 | TE0808-05-BBE21-EK | #3 | TE0808-05-BBE81-EK |
TE0808-05-BBE21-AS | #1, #3 | - | - | TE0808-05-BBE81-ES |
TE0808-05-BBE21-AZ | #1, #2, #3 | - | - | TE0808-05-BBE81-E |
TE0808-05-BBE81-A | #1 | - | - | TE0808-05-BBE81-E |
TE0808-05-BBE81-AK | #1 | - | - | TE0808-05-BBE81-EK |
1) Intermediate products are delivered on demand for customers who are not able to switch to replacements on the short term.
...
Impact: New programming file is necessary. Trenz reference design consideres new PLL programming information but custom programming files needs to be updated by customer. For more information take a look at AN1006-Si534x-8x-RevB-RevD-Differences.
#2 Changed DCDC (U15, U20, U21, U22, U23, U24, U29, U30, U31, U35, U36, U38, U45) from MUN3CAD03-SE to TPS82085SIL and adapted voltage divider resistors.
Type: BOM Change
Reason: TPS82085SIL availability.
Impact: Minor changes in electrical characteristics.
#3 Changed DDR4 SDRAM (U2, U3, U9, U12) from K4A8G165WB-BIRC to K4A8G165WC-BITDTCV.
Type: BOM change
Reason: BOM Optimization.
Impact: New DDR timings may be considered in designs. DDR4 setup used in reference design is known to work still.