Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

CPLD Device: LCMX02-256HC. Firmware with Standard DIPFORTY Configuration for XMOD.

Note

This firmware is for XMOD with usage on TE0722-DIPFORTY only!

 

Feature Summary

JTAG routing

...

Name / opt. VHD NameDirectionPinDescription
Ainout8XMOD Pin Header / UART RXD (input to adapter)TCK
ACBUS4 27FTDI / currently_not_used
ACBUS5 28FTDI / currently_not_used
ADBUS4 5FTDI / currently_not_used
Bout12XMOD Pin Header / UART TXD (output from adapter)TMS
BDBUS2in21FTDI / currently_not_used
BDBUS3out20FTDI / currently_not_used
Coutin9XMOD Pin Header / UART RXD (input to adapter)
Dinout11XMOD Pin Header / UART TXD (output from adapter)
Ein14XMOD Pin Header / TDO
Fout13XMOD Pin Header / TDI
FT_B_RX / BDBUS1out25FTDI
FT_B_TX / BDBUS0in23FTDI
Gin17XMOD Pin Header / Pushbutton S1
Hout16XMOD Pin Header / currently_not_used
JTAGENin26Enable JTAG access to CPLD for Firmware update (zero: normal IOs, one: CPLD JTAG access). Selectable over S2-1
TCK / ADBUS0in30FTDI
TDI / ADBUS1in32FTDI
TDO / ADBUS2out1FTDI
TMS / ADBUS3in29FTDI
ULEDout10LED D4 (RED)
XCLKin412 MHz OSCI Ref CLK / currently_not_used

...

UART is routed through the CPLD.

 OutputInput
BDBDBUS0
BDBUS1AC

LED

ULED D4 (RED) is E xor not G

Appx. A: Change History and Legal Notices

Revision Changes

  • REV01 to older REV01
    • set LED to not G only (removed E connection)
    • removed unused port H
    • no logical changes

Document Change History

To get content of older revision  got to "Change History"  of this page and select older document revision number.

DateDocument RevisionCPLD Firmware RevisionSupported PCB RevisionAuthorsDescription

Page info
modified-date
modified-date
dateFormatyyyy-MM-dd

Page info
current-version
current-version
prefixv.


 

REV01REV02

Page info
modified-users
modified-users

REV01 finished
2016-04-1126

v.1

---REV02

Page info
created-user
created-user

Initial release
 All  
 

...