- Unzip project files
- Rename basefolder (basefolder name is used as project name)
- Edit start design_basic_settings.cmd
- Select the correct Xilinx Program path (See: Windows Command Files → design_basic_settings.cmd)
- Select the correct board part number for your PCB (See: Windows Command Files → startdesign_basic_settings.cmd)
- Other settings are optional (See: Windows Command Files → startdesign_basic_settings.cmd)
- Excecute vivado_create_project_firstguiguimode.cmd or vivado_create_project_noguibatchmode.cmd to generate a vivado project with the predefined block_design Block Design from the block_design Block Design folder
- Open Vivado with with vivado_open_existing_project_guiguimode.cmd (if you use vivado_create_project_firstguiguimode.cmd on step 4, you didn't need this)
- Open the Block Design and create your own design inside this Block Design.
- Backup your Block Design as tcl-script: Type "TE::hw_blockdesign_export_tcl" on Vivado Tcl Console. The old one will be overwritten.
- Build your Design...
Initial scripts on existing Vivado/LabTool project
- Variant 1 (recommended):
- Start the project with the predefined command file (vivado_open_existing_project_guiguimode.cmd.cmd) respectively LabTools with (vivado_labtoolslabtools_open_project_guimode.cmd)
- Variant 2:
- Create your own Initialisation Button on the Vivado GUI:
- Tools → Customize Commands → Customize Commands...
- Push
- Type Name ex.: Init Scripts
- Press Enter
- Select Run command and insert:
- for Vivado: cd [get_property DIRECTORY [current_project]]; source -notrace "../scripts/reinitialise_all.tcl"
- for LabTool: cd [pwd]; source -notrace "../scripts/reinitialise_all.tcl"
- Press Enter
- A new Button is shown on the Vivado Gui: All Scripts are reinitialised, if you press this Button.
- Variant 3:
- Reinitialise Script on Vivado TCL-Console:
- Type: source ../scripts/reinitialise_all.tcl
...