CompanyTrenz Electronic GmbH
PCN NumberPCN-20230322
TitleTE0722-02 to TE0722-03 Hardware Revision Change
SubjectHardware Revision Change
Issue Date

2023-0607-01

Products Affected

This change affects all Trenz Electronic TE0722 SoMs: TE0722-02*.

...

Reason: EOL of Component.

Impact: None.

#3 Removed proximity/ambient light sensor Si1143-A11-GMR (U4) and circuit components (D1, D3, D5, R6, and R20).

Type: Schematic Change

Reason: EOL of Component.

Impact: Sensor is no longer available. Firmware reflects it but custom firmware needs to be updated by customer.

#4 Added resistors (R37, R38, R39) assembly option to prepare proximity/ambient light sensor (U4) circuit for Si115x usage.

Type: Schematic Change

Reason: EOL of Si1143-A11-GMR.

...

Reason: Use AMD boot mode name convention.

Impact: None.

#9 Modified testpoints : Added (TP4, TP5

...

) / Changed size from 1 mm to 0.8 mm diameter (TP1, TP2, TP3, TP7

...

, TP8).

Type: PCB Change

Reason: Use standard testpoints.

...

Method of Identification