This change affects all Trenz Electronic TE0600 SoMs: TE0600-03*.
Affected Product | Replacement |
---|---|
TE0600-03-72C11-A | TE0600-04 |
1) Leds D1 , D5 were changed from 150060VS75000 to SML-P11MTT86
2) R83 was added. R29 was changed from 2.2k to 100
3) U9 was changed from SiT8008AI to SiT8008BI
4) D3 was changed from single BAT54VV,115 to pair BAT54A,215
5) U2 was changed from EN6347QI to MPM3860GQW-Z
6) U3 was changed from EP53F8QI to MPM3834CGPA
7) Stacked vias were removed
8) Net BR0 was connected to GND
9) B2B signal groups information was added
10) Field filename was renamed for all schematic pages
11) Legal Notices page was added
12) System overview and power-on sequencing were added for TE0600.SchDoc page
13) Testpoints TP11 - TP14 , TP23 - TP28 were added
14) R56, R57, R58 were changed from 2k2 to 2k4
15) U12 was fitted for all module assembly variants
16) R36 was changed from 120R to 240R, R84 and T1 were added
17) U4 and U14 were changed from LP3878SD-ADJ to TPS74601PBDRVT
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
Impact:
Type:
Reason:
-72C11-A | |
TE0600-03-72C21-A | TE0600-04-72C21-A |
TE0600-03-52I11-A | TE0600-04-52I11-A |
TE0600-03-83I21-A | TE0600-04-83I21-A |
TE0600-03-52I11-M | TE0600-04-52I11-M |
TE0600-03-83I11-A | TE0600-04-83I11-A |
TE0600-03-83C21-A (???) | TE0600-04-83C21-A |
TE0600-03-52I11-W (nicht produziert) ??? | EOL |
TE0600-03-52I11-C (nicht produziert, müsste S-Variante sein) ??? | EOL |
TE0600-03IC ??? |
Note ED: 3) U9 was changed from SiT8008AI to SiT8008BI (ED: not changed for replacement variants)
Type: Schematic Change
Reason: EOL of Component.
Impact: None. Increased current output capability. Minor changes in electrical characteristics.
Type: Schematic Change
Reason: EOL of Component
Impact: None. Minor changes in electrical characteristics.
Type: Schematic Change
Reason: EOL of Component
Impact: None. Increased current output capability. Minor changes in electrical characteristics.
Type: BOM Change
Reason: ???
Impact: ???
Type: Schematic Change
Reason: Improvement.
Impact: None. Default is as previous revision.
Type: Schematic Change
Reason: Improve led circuit.
Impact: None.
Type: BOM Change
Reason: Follow AMD recommendation.
Impact: None.
Type: Schematic Change
Reason: BOM optimization.
Impact: None.
Type: Schematic Change
Reason: BOM optimization.
Impact: None.
Type: BOM Change
Reason: Follow AMD recommendation.
Impact: None.
Type: Schematic Change
Reason: Update revision information.
Impact: None. Firmware reflects it but custom firmware needs to be updated by customer.
Type: PCB Change
Reason: Improve voltage monitoring.
Impact: None.
Type: PCB Change
Reason: Reliability improvement.
Impact: Reliablity improvement.
Type: PCB change
Reason: Result of changes above.
Impact: Changed trace length have to be taken into account in existing designs.
Type: Documentation Update
Reason: Documentation improvement.
Impact: None.
Type: Documentation Update
Reason: Documentation improvement.
Impact: None.
Type: Documentation Update
Reason: Documentation improvement.
Impact: None.Impact:
Scroll Pagebreak |
---|
...
If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at
phone
national calls: 05741 3200-0
international calls: 0049 5741 3200-0
Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.
...