Overview

Scroll Only (inline)
Refer to https://shop.trenz-electronic.de/de/Download/?path=Trenz_Electronic/PMOD/TEP0001 for online version of this manual and other documents available about the product.
 

The Trenz Electronic TEP0001 is an industrial-grade dual CAN FD transceiver with Pmod interface.

Features

  • Digilent Pmod interface compatible
  • Dual CAN FD PHY's (CAN0 and CAN1)
    • Texas Instruments TCAN337G
    • Up to 5Mbit data rate
    • Compatible with ISO 11898-2
    • Bus pin fault protection of ±14 V
    • Integrated 12 kV IEC-61000-4-2 ESD contact discharge protection

    • 10 pin headers (IDC cable to DB9)
    • One CAN FD transceiver has extra 3-pin screw connector terminal
  • Single 3.3V supply

Main Components

 

  • J1. Screw connector terminal of CAN0 bus
  • J2. 2.54mm pitch 2x6-pin header Pmod interface
  • J3. 2.54mm pitch 2x5-pin box header, CAN0 bus
  • J4. 2.54mm pitch 2x5-pin box header, CAN1 bus
  • J5. 2.54mm pitch SMT 2x3-pin jumper block, can also be used as CAN1 bus connector
  • J6. 2.54mm pitch SMT 2x3-pin jumper block, can also be used as CAN0 bus connector
  • U1. Texas Instruments TCAN337G CAN FD transceiver, CAN0
  • D1. Bourns CDSOT23-T24CAN CANbus Protector, CAN0
  • U2. Texas Instruments TCAN337G CAN FD transceiver, CAN1
  • D2. Bourns CDSOT23-T24CAN CANbus Protector, CAN1
Note

TEP0001 PMOD connector is mounted for Right Angle connection to PMOD Baseboard.

Interfaces and Pins

J1 Connector, CAN0 Bus

PinSignalNotes
1CAN0_HU1 high level CAN bus line
2GNDU1 ground connection
3CAN0_LU1 low level CAN bus line

J2 Connector, Pmod Interface

PinSignalNotes PinSignalNotes
1CAN0_TX

U1 CAN0 transmit data input,

integrated pull up

 2CAN1_TX

U2 CAN1 transmit data input,

integrated pull up

3CAN0_RX

U1 CAN0 receive data output, tri-state

 4CAN1_RX

U2 CAN1 receive data output, tri-state

5CAN0_S

U1 silent mode,integrated pull down

 6CAN1_S

U2 silent mode, integrated pull down

7CAN0_FU1 open drain fault output 8CAN1_FU2 open drain fault output
9GNDU1 ground connection 10GNDU2 ground connection
113.3VU1 3.3V supply voltage 123.3VU2 3.3V supply voltage

J3 Connector, CAN0 Bus

PinSignalNotes PinSignalNotes
1N/A- 2GNDU1 ground connection
3CAN0_LU1 low level CAN bus line 4CAN0_HU1 high level CAN bus line
5GNDU1 ground connection 6N/A-
7N/A- 8N/A-
9N/A- 10N/A-

J4 Connector, CAN1 Bus

PinSignalNotes PinSignalNotes
1N/A- 2GNDU2 ground connection
3CAN1_LU2 low level CAN bus line 4CAN1_HU2 high level CAN bus line
5GNDU2 ground connection 6N/A-
7N/A- 8N/A-
9N/A- 10N/A-

J5 Jumper Block/Connector CAN1 bus

Close pins 1-3 and 2-4 with jumpers to enable on-board terminator for CAN1 bus. J5 header can also be used as CAN1 bus connector, refer to the following table pin mapping.

PinSignalNote PinSignalNote
3CAN1_LU2 low level CAN bus line 4CAN1_HU2 high level CAN bus line
5GNDU2 ground connection 6GNDU2 ground connection

J6 Jumper Block/Connector, CAN0 bus

Close pins 1-3 and 2-4 with jumpers to enable on-board terminator for CAN0 bus. J6 header can also be used as CAN0 bus connector, refer to the following table for pin mapping.

PinSignalNote PinSignalNote
3CAN0_LU1 low level CAN bus line 4CAN0_HU1 high level CAN bus line
5GNDU1 ground connection 6GNDU1 ground connection

Operating Conditions, Ratings and Dimensions

Recommended Operating Conditions

 MinimumMaximumUnit
Supply voltage33.6V
Operational free-air temperature-40125°C

Absolute Maximum Ratings

ParameterMinimumMaximumUnit
Supply voltage range-0.35

V

Voltage at any bus terminal (CANH or CANL)-1414V
Operating temperature range-40150°C
Storage temperature-150°C
Info

Refer to Texas Instruments TCAN337G product datasheet for additional information about conditions and ratings.

Power Requirements

3.3V supply voltage TBD* (180 mA max per one CAN FD transceiver in "Normal Mode", dominant state with bus fault as per TCAN337G datasheet).

* TBD - To Be Determined soon with reference design setup.

Physical Dimensions

  • Module size: 54 mm × 20.5 mm.

  • Mating height of the J2 connector from the PCB: 8mm

  • PCB thickness: 1.6mm

  • Highest parts on PCB are J1, J3 and J4 connectors, approximately 9.5mm from the PCB.

Revision History

Hardware Revision History

DateRevision

Notes

PCN
2016-08-22

01

Initial batch

 -

Hardware revision number is printed on the PCB board next to the module model number separated by the dash.

 

Document Change History

Date

Rrevision

Contributors

Description

2016-09-05
Initial document.

Disclaimer