Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • only allowed to be used for electrical specialist for the used electrical voltage and power conditions
  • only allowed to be used under electrical laboratory conditions
  • only allowed to be used in horizontal position on a non-conducting and non-inflammable surface
  • only allowed to be used with a wiring, which fulfills the current rating for the maximum possible currents.
  • only allowed to be used with a suitable current limiting circuit such that the maximum continuous current does not exceed 30A as follows:
    • The delivered fuse "Littelfuse Type 142.5631.5302" must be used as current limiter between connectors J5 and J6.
    • To limit the current for smaller motor loads an ADDITIONALL appropriate current limiter can be used e.g. a current limited power source or a fuse integrated in the wiring.
  • only allowed to be used with appropriate connectors at the M5 screw connectors, which means M5 cable lugs must be used and fastened according to technical standards.
  • only allowed to be used, if the "Drive Boad high current signals" conducting up to 30A nominal, are covered by isolating, mechanically stable, non-inflammable (UL V-1 or better) material
    • The "Drive Board high current signals" are the motor outputs A, B, C and Fuse F1 Connectors J5 an J6 and further internal connections shown white marked in the following picture:

Image Modified

Figure 5: High-current parts of the TEC0053.

Warning
It is mandatory to use the delivered isolating cover of the PCB made of plexiglass as a minimum protection. Use holes H1, H9, H3 and H4 with the delivered 10mm spacers when mounting.


Image Modified

Figure 6: Top view of the Board with isolating transparent plexiglass cover attached.

...