Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Changes

#1 Replaced U8 by EN6338QI

Type: BOM Change

Reason: Improve fault rate

Impact: None

#2 Changed track length of V3_IO_06 and V3_IO_07 

Type: Layout change

Reason: Rerouted nets around U8

Impact: Applications with strict timings/length mached tracks have to consider new SoM track length. Signal V3_IO_06 15.2475 mm (was 15.0047mm), Signal V3_IO_07 16.0151 mm (was 15.0452 mm)

#3 Replaced U5 by EN6338QI

Type: BOM Change

Reason: Improve fault rate

Impact: None

#4 Added OR gate on PS_EN signal

Type: Schematic Change

Reason: Improve fault rate

Impact: None

#5 Replaced Diodes D1, D2, D4, by BAT54A

Type: BOM change

Reason: Former diodes obsolete

Impact: None

#6 Updated Footprint of  U10

Type: PCB change

Reason: Improve production yield

Impact: None

#7 Update from LIB

Type: PCB change

Reason: Improve production yield

Impact: None

#8 Rearranged Testpoints

Type: Layout change

Reason: Optimize testing

Impact: Testpoints have new locations

#9 Added Traceability Pad

Type: BOM change

Reason: Allow automated identification of module

Impact: None

#10 Replaced S5 by smaller push button B3U-1100P

Type: BOM change

Reason: Conflict with screws reported

Impact: Changed z-dimension has to be considered for housings


#11 Board

Revision Coding Updated

revision coding updated to REV02

Type: Schematic Change

Reason: New Revisionrevision

Impact: If revision hardware coding of board revision is used in designsdesign, update is needed.

Method of Identification

The model code and revision number (e.g. TE0630-01 or TE0630-02) are printed on the top side of the PCB.