CompanyTrenz Electronic GmbH
PCN NumberPCN-20201007
TitleTE0803-03 to TE0803-04 Hardware Revision Change
SubjectHardware Revision Change
Issue Date

2021-02-0508

Products Affected

This change affects all Trenz Electronic TE0803 SoMs of revision 03:

Affected Product

Replacement
TE0803-03-*TE0803-04-*

Changes

#1

...

PL_VCCINT power supply

...

U4 replaced by TPS548A28RWWR

...

Type: PCB Schematic change
Reason: In Minimize solution footprint and cost optimization.
Impact:  revised routing and components placement;Up to 15A VCCINT possible. Height profile of the module is changed.

#2 Added support of wide DDR4 SDRAM

...

packages

...

Type: PCB change
Reason: In Support of new packages of DDP DDR4 ICs.
Impact: revised routing and components placement

...

DDP DDR4 now supported.

#3 Add resistors R12 and R93

...

Type: PCB Schematic change
Reason: InAdd option to select POR_OVERRIDE level.
Impact: UsFor all standard variants R93 is fitted and R12 is not fitted. With this setting the behavior is the same as in previous revision. Custom variants 4BI21-X and 4BI41-X have R12 fitted and R93 not fitted.

#4 Unused VCCO pins

...

connected together

...

within Bank 24 and Bank44

Type: PCB Schematic change
Reason: Xilinx recomendation UG583.
Impact: UsNone.

#5

...

Signal trace lengths

...

changed

Type: PCB change
Reason: In Result of changes above.
Impact: UsChanged tracelength have to be taken into account in existing designs. The tracelength for new revision are added to the TE080X series pinout generator.

#6 Added company address, CE and WEEE symbols

...

Type: PCB Silkscreen change
Reason: In Mandantory.
Impact: UsNone.

#7 Added module orientation pointer

Type: PCB change
Reason: Correct orientation of SoM on baseboard not obvious.
Impact: Implementing a similar pointer on a carrier PCB will hopefully lower the number risk of attempts to mount mounting the module missorientedwrongly oriented.

#8 Changed resistors value of R29, R31, R35, R39, R44-R47

...

Type: BOM change
Reason: Part is end of life.
Impact: Track it pad no more available.


Note: Due to the changes above the height profile of the module is changed. Using TE0803-04 board as a replacement or in system designed for TE0803-03, review and adaption of mechanics e.g. cooling solutions have to be done. KK0803-03 is not compatible with TE083-04. A new revision of the heat spreader for revision 04 of TE0803 will be released.

Method of Identification

The revision number is printed on the top side of the PCB.

draw.io Diagram
bordertrue
diagramNameTE0803-04_HRN
simpleViewerfalse
width
linksauto
tbstyletop
lboxtrue
diagramWidth220
revision1

Production Shipment Schedule

Revison The new revison 04 is available from mid of November 2020,  if you still need the revision 01 please contact usOctober 2021. Revision 03 is still continued. For new designs revison 04 should be used. It is recommended to switch to the new revision when possible.


Contact Information

If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at

Disclaimer

Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances.  For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.

...