Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
CompanyTrenz Electronic Gmbh
PCN NumberPCN-20140730
TitleTE0720-01 to TE0720-02
SubjectTrenz Electronic TE0720 SoM (system on module): revision 1 to revision 2 upgrade
Issue Date

20140730

Products Affected

This change affects all Trenz Electronic TE0720 SoMs of the first revision: TE0720-01-*.

affected product

suggested upgrade

TE0720-01-*

TE0720-02-*

Changes

 

Type
Impact

Description
Reason for change

#1

Enhancement

JTAG only boot mode is now supported

 None

Type: Enhancement

Reason: Enhancement of functionality

#2Enhancement

Impact: None

#2 Winbond W25Q256FV SPI Flash memory replaced with Spansion S25FL256

 

May have to re-evaluate applications

that write to the SPI Flash

Type: Enhancement

Reason: Spansion S25FL256 is supported by current Xilinx design tools (ISE14.7, Vivado)

W25Q256 is only supported by u-boot, linux and Vivado SDK Programmer

#3BOM change

Impact: May have to re-evaluate applications that write to the SPI Flash

#3 Texas Instruments TPS51200 Sink/Source DDR Termination Regulator replaced with TPS51206

 None

Type: BOM change

Reason: TPS51206 was changed due to BOM optimization

Impact: None

#4

BOM change

Changed MDIO pullup from 10k to 4k7

 None

Type: BOM change

Reason: Avoiding potential problems when PHY management bus is configured at high speeds

#5Schematic change

Impact: None

#5 Changed eMMC core supply from switched 3.3Vout to 3.3Vin

 None

Type: Schematic change

Reason: eMMC startup timing improvement

#6Schematic change

Impact: None

#6 MAC EEPROM power changed from 3.3V to 1.8V

 None

Type: Schematic change

Reason: PCB and System Controller optimization

Impact: None

#7

Schematic change

I2C Multiplexing no longer needed (to select between RTC and MEMS), all

I2C devices are on the same bus.

 

Type: Schematic change

Reason: Change to new type of MEMS with only one I2C

Impact: None (if the old GPIO based I2C mux is used it just has no effect now)

Change to new type of MEMS with only one I2C

#8

BOM change

ST LSM303DLM (e-compass: 3D accelerometer and 3D magnetometer) MEMS

is no longer assembled in standard assembly variants

 

Type: BOM change

Reason: ST LSM303DLM MEMS has been discontinued

Impact: None for designs that did not use the MEMS sensor

ST LSM303DLM MEMS has been discontinued

, please contact us for customized BOM if necessary

#9

#9Layout change

Removed test pads on top layer

 None (test pads only used at factory)

Type: Layout change

Reason: No longer needed as the System Controller factory programming is done during tests using main B2B Connectors

Impact: None (test pads only used at factory)

 

#10EnhancementIncreased component clearance from mounting holes on bottom layer
 NoneDecreasing the possibility to damage the module with improper extraction methods
#11EnhancementSystem Controller in-system programming via B2B JTAG pins
 NoneEnhancement for Factory tests and programming
#12Enhancement

JM1 pin 89 has new function that enables System Controller JTAG Chain,

no impact for old designs that connect this pin to GND

 NoneEnhancement for Factory tests and programming

 

Method of Identification

The model code and revision number (e.g. TE0720-01 or TE0720-02) are printed on the top side of the PCB.

Production Shipment Schedule

From June 2014.

Contact Information

If you have any questions related to this PCN, please contact Trenz Electronic's Technical Support at

Disclaimer

Any projected dates in this PCN are based on the most current product information at the time this PCN is being
issued, but they may change due to unforeseen circumstances.  For the latest schedule and any other information,
please contact your local Trenz Electronic sales office, technical support or local distributor.