XADC can also be monitored to check the temperature and voltage sensor values.

TE0720

Image Added

B2B I/O Pins: TE0720 is on TE0703 baseboard with no user specified VCCIO supplied for banks B13, B33, B35 - unpowered banks Read Inputs as 0 (despite the IO pullups), only B34 reads inputs as high as this bank is powered (J5 is set on TE0703)

 

Image Added

Clock measurements: 125MHz is Clock from Ethernet PHY, CFGCLK is FPGA internal configuration clock (nominal frequency 66MHz). TE0720 has no fixed PL clock sources, so the labtools design uses free running clock for all VIO's and PS supplied clock FCLK0 or FCLK3 as reference clock (it can be selected by changing PLL_REFSEL to 1 for FCLK0).