Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

LED3 D7 Red (near FAN1 connector on PCB)
Bode ModeBlink SequenceComment
Error********ATX Power failed or PCB is powered offERROR
JTAG*****oooModule Low Power Domain failedJTAG
PJTAG0****ooooModule Full Power Domain failedBoot Mode is set to PJTAG0
eMMC***oooooModule PL Power Domain failedBoot Mode is set to eMMC
SPI Boot**ooooooCarrier 1V8 or FMC VADJ Power Domain failedBoot Mode is set to QSPI
SD Boot*oooooooModule DDR, PL GT, PS GT or PLL Power Domain failedBoot Mode is set to SD

ONReset is on


XMOD LED  Red (XMOD1 on J12 with green dot)
StatusBlink SequenceComment
PS_INIT_B********

Indicates the PS is initialized after a power-on reset (POR).

PS_ERROR_OUT*****ooo

The PS_ERROR_OUT signal is asserted for accidental loss of power, an error, or an exception in the PMU.

DONEON or OFF

Indicates the PL configuration is completed (LED is OFF).

...