LED3 D7 Red (near FAN1 connector on PCB) | ||
---|---|---|
Bode Mode | Blink Sequence | Comment |
Error | ******** | ATX Power failed or PCB is powered offERROR |
JTAG | *****ooo | Module Low Power Domain failedJTAG |
PJTAG0 | ****ooooModule | Full Power Domain failedBoot Mode is set to PJTAG0 |
eMMC | ***oooooModule PL Power Domain failed | Boot Mode is set to eMMC |
SPI Boot | **ooooooCarrier 1V8 or FMC VADJ Power Domain failed | Boot Mode is set to QSPI |
SD Boot | *oooooooModule DDR, PL GT, PS GT or PLL Power Domain failed | Boot Mode is set to SD |
ON | Reset is on |
XMOD LED Red (XMOD1 on J12 with green dot) | ||
---|---|---|
Status | Blink Sequence | Comment |
PS_INIT_B | ******** | Indicates the PS is initialized after a power-on reset (POR). |
PS_ERROR_OUT | *****ooo | The PS_ERROR_OUT signal is asserted for accidental loss of power, an error, or an exception in the PMU. |
DONE | ON or OFF | Indicates the PL configuration is completed (LED is OFF). |
...