Page History
...
Scroll Only (inline) |
---|
Online version of this manual and other related documents can be found at https://wiki.trenz-electronic.de/display/PD/TEF0008+MAX10 |
Scroll pdf ignore | ||||
---|---|---|---|---|
Table of contents
|
...
Product Specification
Port Description
Name / opt. VHD Name | Direction | Pin | weak pullup | Description |
---|---|---|---|---|
PLL_SDA_io | Bidir | K2 | I2C Si5345A-B | |
PLL_SCL_o | Out | K1 | I2C Si5345A-B | |
LED | Out | C2 | Status LED | |
A_LOS_i | In | H9 | SFP A Signal Loss (HIGH indicates signal loss) | |
A_MDEF0_i | In | G9 | SFP A |
Module Absent (HIGH when module physically absent) | ||||
A_RS0_o | Out | J9 | SFP A Rate Select RX (LOW for 1000BASE-SX, HIGH for 10GBASE-SR) | |
A_RS1_o | Out | H8 | SFP A Rate Select TX (LOW for 1000BASE-SX, HIGH for 10GBASE-SR) | |
A_SCL_o | Out | K10 | SFP A I2C Clock | |
A_SDA_io | Bidir | K11 | SFP A I2C Data | |
A_TX_DIS_o | Out | H10 | SFP A (HIGH disables transmitter) | |
A_TX_FAULT_i | In | L12 | SFP A Laser Fault (HIGH indicates fault) | |
B_LOS_i | In | K12 | SFP B Signal Loss (HIGH indicates signal loss) | |
B_MDEF0_i | In | J13 | SFP B |
Module Absent (HIGH when module physically absent) | ||||
B_RS0_o | Out | J12 | SFP B Rate Select RX (LOW for 1000BASE-SX, HIGH for 10GBASE-SR) | |
B_RS1_o | Out | L13 | SFP B Rate Select TX (LOW for 1000BASE-SX, HIGH for 10GBASE-SR) | |
B_SCL_o | Out | H13 | SFP B I2C Clock | |
B_SDA_io | Bidir | G10 | SFP B I2C Data | |
B_TX_DIS_o | Out | G13 | SFP B (HIGH disables transmitter) | |
B_TX_FAULT_i | In | G12 | SFP B Laser Fault (HIGH indicates fault) | |
C_LOS_i | In | F12 | SFP C Signal Loss (HIGH indicates signal loss) | |
C_MDEF0_i | In | E12 | SFP C |
Module Absent (HIGH when module physically absent) | ||||
C_RS0_o | Out | F13 | SFP C Rate Select RX (LOW for 1000BASE-SX, HIGH for 10GBASE-SR) | |
C_RS1_o | Out | F9 | SFP C Rate Select TX (LOW for 1000BASE-SX, HIGH for 10GBASE-SR) | |
C_SCL_o | Out | E13 | SFP C I2C Clock | |
C_SDA_io | Bidir | D11 | SFP C I2C Data | |
C_TX_DIS_o | Out | D12 | SFP C (HIGH disables transmitter) | |
C_TX_FAULT_i | In | C12 | SFP C Laser Fault (HIGH indicates fault) | |
D_LOS_i | In | B11 | SFP D Signal Loss (HIGH indicates signal loss) | |
D_MDEF0_i | In | B12 | SFP D |
Module Absent (HIGH when module physically absent) | ||||
D_RS0_o | Out | B13 | SFP D Rate Select RX (LOW for 1000BASE-SX, HIGH for 10GBASE-SR) | |
D_RS1_o | Out | C13 | SFP D Rate Select TX (LOW for 1000BASE-SX, HIGH for 10GBASE-SR) | |
D_SCL_o | Out | A12 | SFP D I2C Clock | |
D_SDA_io | Bidir | F10 | SFP D I2C Data | |
D_TX_DIS_o | Out | E9 | SFP D (HIGH disables transmitter) | |
D_TX_FAULT_i | In | D9 | SFP D Laser Fault (HIGH indicates fault) | |
LA00_P | In | M9 | ON | SCL In |
LA00_N | In | N5 | ON | SDA In |
LA01_P | Out | L4 | SDA Out | |
LA01_N | In | J5 | ON | I2C |
MUX 0: SEL[0] | ||||
LA02_P | In | M13 | ON | I2C |
MUX 1: SEL[1] | ||||
LA02_N | In | M12 | ON | I2C |
MUX 2: SEL[2] | ||||
LA03_N | In | N6 | ON | RS0 |
LA03_P | In | M5 | ON | TX_DISABLE |
LA04_N | Out | K7 | TX Fault A+B+C+D | |
LA04_P | In | J7 | ON | RS1 |
LA05_N | Out | L5 | LOS A | |
LA05_P | Out | K5 | DEF0 A, SFP A Inserted Flag | |
LA06_N | Out | J6 | LOS B | |
LA06_P | Out | K6 | DEF0 B, SFP B Inserted Flag | |
LA07_N | Out | M8 | LOS C | |
LA07_P | Out | N8 | DEF0 C, SFP C Inserted Flag | |
LA08_N | Out | M7 | LOS D | |
LA08_P | Out | N7 | DEF0 D, SFP D Inserted Flag | |
LA09_P | - | N4 | /currently unused | |
LA09_N | - | M4 | /currently unused |
Functional Description
SFP Control
- Input Signal LA03_N sets all four SFP RX modes (LA03_N=HIGH sets RS0 signals LOW for 1000BASE-SX, LA03_N=LOW sets RS0 signals HIGH for 10GBASE-SR)1
- Input Signal LA04_P sets all four SFP TX modes (LA04_P=HIGH sets RS1 signals LOW for 1000BASE-SX, LA04_P=LOW sets RS1 signals HIGH for 10GBASE-SR)1
- Output Signals LA05_N, LA06_N, LA07_N and LA08_N indicate signal loss of SFP A, B, C and D respectively (HIGH indicates signal loss).
- Output Signals LA05_P, LA06_P, LA07_P and LA08and LA08_P indicate SFP A, B, C and D module absend absent (HIGH when module physically absent).
- Output Signal LA04_N is HIGH when at least one of the four SFPs indicate Laser fault.
- Input LA03_P HIGH sets for all SFPs where the module is physically available (MDEF0_i is LOW) the TX_DIS signal to LOW.2
1SFP Control and I2C register writes of RX/TX modes are couppled with a logical or. If at least one of them indicates HIGH the 10GBASE-SR is activated.
- 1
12Inverted control as we can not enable weak pulldown in MAX10, we use weak pullup. E.g. TX are all ENABLED at default power up, so the card is working with no FMC LA pin driven.
...
- LA00_P, LA00_N and LA01_P form a "three wire I2C" bus with seperate separate data in and output.
- LA01_N, LA02_P and LA02_N are used as selector for the MUX.
SEL | I2C device |
---|---|
000 | SFP A |
001 | SFP B |
010 | SFP C |
011 | SFP D |
100 | Si5345 Clock Generator |
For I2C adresses addresses see TEF0008 TRM.
LED
LED is used as Status LED and is on if at least on SFP is connected.
...
MAX10 JTAG for programming is always enabled and accessible via the FMC connector, pin header J3 and testpointstest points.
Appx. A: Change History and Legal Notices
...
Date | Document Revision | CPLD Firmware Revision | Supported PCB Revision | Authors | Description | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| modified-date |
| modified-
|
| current-version |
| current-
| REV01 | REV01, REV02 |
|
| ||||||||||||||||||||||||||||||
2018-08-27 | v.05 | REV01 | REV01, REV02 |
| |||||||||||||||||||||||||||||||||||||
2018-08-07 | v.1303 | REV01 | REV01 | John Hartfiel |
| ||||||||||||||||||||||||||||||||||||
2018-06-07 | v.01 | REV01 | REV01 | Martin Rohrmüller |
| ||||||||||||||||||||||||||||||||||||
All |
|
...
Overview