CompanyTrenz Electronic GmbH
PCN NumberPCN-20220718
TitleAM0010-01 to AM0010-02 Hardware Revision Change
SubjectHardware Revision Change
Issue Date

2022-07-3022

Products Affected

This change affects all Trenz Electronic AM0010 SoMs: AM0010-01*.

AM001002-

Affected Product

Replacement
AM0010-01-2AE21FA-2AE21MAAM0010-01-2AE21MAAM0010-02-2AE21MAAM0010-01-3BE21FA
AM0010-02-3BE21MAAM0010-01-3BE21MAAM0010-02-3BE21MAAM0010-01-3BI21FA
AM0010-02-3BI21MAAM0010-01-3BI21MAAM0010-02-3BI21MA
AM0010-01-4AE21MAAM0010-02-4AE21MA
AM0010-01-4BE21MAAM0010-02-4BE21MA
AM0010-01-4DE21FAAM0010-02-4DE21MAAM0010-01-4DE21MAAM0010-02-4DE21MA

Changes

#1 Added support for speedgrade -3.

Type:Improvement  Schematic Change

Reason: Product Improvement

Impact: None, assembly options with additional DCDC for speedgrade -3 devices possible.

#2 Changed TPS54A24RTWR to MPQ8633BGLE-Z for U18.

Type: BOM Schematic Change

Reason: BOM Optimization

Impact: None.

#3 Changed USB PHY from USB3340 to USB3320  for U10 as default option.

Type: BOM Change

Reason: USB PHY usage improvement.

Impact: None.

#4 Added UKCA logo.

Type: BOM Change

Reason: Updated to last requierements.

Impact: None.

...

Minor changes in electrical characteristics, e.g. changed switching frequency, maximum current capability is slightly increased.

#3 BOM Optimization for components (R32, R68, R69, R72, R74, R76, R73, R45, R20, C98, C234, C235, C99, C97, C129, C236, R120, C237, C95, C96, C223, C224, C233, L11, L12, L13).

Type: BOM Schematic Change

Reason: BOM Optimization.

Impact: None.

...

#4 Changed pin connection for U16 pins B5 and C5.

Type: ImprovementSchematic Change

Reason: Connect pins B5 and C5 according to the datasheet/recommendation.

Impact: None.

...

#5 Added pull-up/-down resistor option (R121, ... R128) for signals MODE0...3.

Type: BOM Schematic Change

Reason: Pull-up/-down option for signals MODE0...3.

Impact: None.

#6 Added UKCA logo.

Type: PCB Change

Reason: Requiered for export to UK.

Impact: None.

#7 Changed USB PHY from USB3340 to USB3320  for U10 as default option.

Type: BOM Change

Reason: USB PHY usage improvement.

Impact: None.

#8 Updated Schematic Information.

Type: Information UpdateDocumentation Change

Reason: Schematic Information have to show newest informationDocumentation in schematic has to reflect points above.

Impact: None.


Scroll Pagebreak

...

Production Shipment Schedule

From January February 2023, after old stock is gone. If the new revision is not suitable for your application and still the former revision of the board is needed, please contact us.

...