Scroll Ignore |
---|
Company | Trenz Electronic GmbH |
---|---|
AVN Number | AVN-2022061020220701.1 |
Title | AVN-20220610.1 TEB0911 AVN20220701.1 TEB0911 readback FAN Sense does not work |
Subject | Information about FAN Sense value over CPLD I2C interface |
Issue Date | 2022-0607-1001 |
Affected Product | Effected Changes |
---|---|
TEB911-01-* | #1,#2 |
TEB911-02-* | #1,#2 |
TEB911-03-* | #1,#2 |
TEB911-04-* | #1,#2 |
Read back of the FAN SENSE pin is currently not possible due to the following problems
...
The problem refers only to the read back , the setting of the current setup. Configure fan speed is not affected by this AVN.
Problem can be solved with following HW changes:
...
Scroll Title | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||||||
|
I2C-get register reading is not possible with CPLD Firmware Version 05 or older. Update of the CPLD Firmware with correct is planned.
We are issuing a new revision o on TEB0911 and will make the necessary changes to future boards.
Scroll Pagebreak |
---|
If you have any questions related to this AVN, please contact Trenz Electronics Technical Support at
phone
national calls: 05741 3200-0
international calls: 0049 5741 3200-0
Any projected dates in this AVN are based on the most current product information at the time this AVN is being issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.
...