Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Table of Contents

Driver Installation

The communication with a module supposes a comport, and therefore a driver is required.
When connecting the module to your computer, windows starts the Automatic driver Installation,
but often the automatic driver installation fails and the driver needs to be installed manually.

So it is best practice to connect the module, give the operation system some time, and check
afterwards in the device manager for the appearance of a "comport" and two devices labelled
"USB Serial Convert A and B".

The device manager can be opened either via a right mouse click onto the windows symbol
or by pressing the windows button and typing device manager.

Image Added

When instead two devices labelled "Arrow USB Blaster" are listed under "other devices", the manual
approach has to be taken.
Image Added

Through a right mouse click on each device, a context menu opens. Chose "Update driver" afterwords chose
"Search automatically for updated driver software", this proper driver installation changes the devices names
into USB Serial Converter A & B, in addition, also the comport is installed.

Check its number (“COMx” ) and memorize it for the later use within the demos.

In dependency to the modules firmware, the driver installation can lead to the appearance of two comports,
in this instance, the higher numbered comport is of importance.

Link for Linux user on how to install the driver "Arrow USB programmer"

Firmware Update

The module TEI0015 is shipped with the Firmware suitable for all Reference designs. TEI0016 and TEI0023 are not preprogrammed, this must be done by user.
This guide is for restoring the firmware to factory condition, in case it has been altered.

For restoring For updating the firmware of the module, one needs:

  • Intel - Quartus prime Lite Edition - Version 18.1
  • Arrow - USB - Blaster-Setup-2.2.exe (Install drivers if not done)
  • the firmware, a *.pof file as part of the compressed demo folder

...


Scroll Title
anchorFigure_OV_BD


Scroll Ignore

draw.io Diagram
bordertrue
viewerToolbartrue
fitWindowfalse
diagramDisplayName
lboxtrue
revision4
diagramNameTEI0015 Quartus prime lite V18.1 marker and start
simpleViewertrue
width600
linksauto
tbstyletop
diagramWidth884


Scroll Only

Image RemovedImage Added



Mark the "Program/Configure" box for the selected file. The programming of the FPGA is executed, when you press the button "Start".