Company | Trenz Electronic GmbH |
---|---|
PCN Number | PCN-20220718 |
Title | AM0010-01 to AM0010-02 Hardware Revision Change |
Subject | Hardware Revision Change |
Issue Date | 2022-07-3022 |
Products Affected
This change affects all Trenz Electronic AM0010 SoMs: AM0010-01*.
Affected Product | Replacement | ||
---|---|---|---|
AM0010-01-2AE21FA | AM0010- | 02-2AE21MA | AM0010-01-2AE21MAAM0010-02-2AE21MAAM0010-01-3BE21FA |
AM0010-02-3BE21MAAM0010-01-3BE21MA | AM0010-02-3BE21MAAM0010-01-3BI21FA | ||
AM0010-02-3BI21MAAM0010-01-3BI21MA | AM0010-02-3BI21MA | ||
AM0010-01-4AE21MA | AM0010-02-4AE21MA | ||
AM0010-01-4BE21MA | AM0010-02-4BE21MA | ||
AM0010-01-4DE21FA | AM0010-02-4DE21MA | AM0010-01-4DE21MA | AM0010-02-4DE21MA |
Changes
#1 Added support for speedgrade -3.
Type:Improvement Schematic Change
Reason: Product Improvement
Impact: None, assembly options with additional DCDC for speedgrade -3 devices possible.
#2 Changed TPS54A24RTWR to MPQ8633BGLE-Z for U18.
Type: BOM Schematic Change
Reason: BOM Optimization
Impact: None.
#3 Changed USB PHY from USB3340 to USB3320 for U10 as default option.
Type: BOM Change
Reason: USB PHY usage improvement.
Impact: None.
#4 Added UKCA logo.
Type: BOM Change
Reason: Updated to last requierements.
Impact: None.
...
Minor changes in electrical characteristics, e.g. changed switching frequency, maximum current capability is slightly increased.
#3 BOM Optimization for components (R32, R68, R69, R72, R74, R76, R73, R45, R20, C98, C234, C235, C99, C97, C129, C236, R120, C237, C95, C96, C223, C224, C233, L11, L12, L13).
Type: BOM Schematic Change
Reason: BOM Optimization.
Impact: None.
...
#4 Changed pin connection for U16 pins B5 and C5.
Type: ImprovementSchematic Change
Reason: Connect pins B5 and C5 according to the datasheet/recommendation.
Impact: None.
...
#5 Added pull-up/-down resistor option (R121, ... R128) for signals MODE0...3.
Type: BOM Schematic Change
Reason: Pull-up/-down option for signals MODE0...3.
Impact: None.
#6 Added UKCA logo.
Type: PCB Change
Reason: Requiered for export to UK.
Impact: None.
#7 Changed USB PHY from USB3340 to USB3320 for U10 as default option.
Type: BOM Change
Reason: USB PHY usage improvement.
Impact: None.
#8 Updated Schematic Information.
Type: Information UpdateDocumentation Change
Reason: Schematic Information have to show newest informationDocumentation in schematic has to reflect points above.
Impact: None.
Scroll Pagebreak |
---|
...