Silicon Labs ClockBuilder Pro software should be used to prepare the register file.  Projects are included on the most reference designs.

Download: ClockBuilder Pro for SI5345

Procedure:

  1. Install and start ClockBuilder
  2. Open "/misc/SI5345/Si5345-RevB-0808-02A-Project.slabtimeproj"
  3. Modify settings
  4. Export → Register File → select C code header → save to file

Note:

  • SI5345-REVB and REVD need different project


I2C Configuration

Volatile memory

...

Therefore SI Clock Builder Pro Software and Clock Builder Pro Field Programmer  are necessary.

Procedure:

  1. Connect GND, I2C-SCL and I2-SDA_SDIO with SI5345 I2C bus of the board.
  2. Connect USB to PC and Power on the module
  3. Open Clock Builder Pro and select NVM Program Tool
  4. Select SI545 project and set correct Host Interface (I2C address and IO Voltage)
  5.  Scan device
  6. Program NVM

Termination

AN408 describes the input termination options for Si5338.

Note