TE0320 is provided with a slide switch S2.
Slide switch S2 conditions the value of signal PS_EN.
In this way, S2 conditionally/unconditionally enables the 1.2 V and 2.5 V power rails.Image Removed
Figure 33:

Scroll pdf title
titleSlide switch S2 (angle view).

...

Image Added

...

Scroll pdf title
title
Slide switch S2 schematic

...

Image Added
Scroll pdf title
titleWhen slide switch S2 = FX2 PON, signal PS_EN is set to signal FX2_PS_EN driven by the EZ-USB FX2LP USB FX2 microcontroller under user control
Image Added

  control.When S2 is turned on (closed, FX2 PON), the power rails 1.2 V and 2.5 V are controlled by the USB (EZ-USB FX2LP USB FX2) microcontroller. At start-up, the USB microcontroller switches off the 1.2 V and 2.5 V power rails and starts up the module in low-power mode. After enumeration, the USB microcontroller firmware enables (switches on) power rails 1.2 V and 2.5 V, if enough current is available from the USB bus. 

When S2 is turned off (open, PON), the 1.2 V and 2.5 V power rails are always enabled (switched on).

Warning
When S2 is turned on (FX2 PON), make sure that no signals are applied to the input pins when power-rails are disabled by the USB microcontroller (at start-up).
Scroll pdf title
titleSlide switch S2 settings overview (power rails 1.2 V and 2.5 V only)

S2 position

Default position

Effect on 1.2 V and 2.5 V rails

FX2 PON (on, closed) 

(tick)

Power rails 1.2 V and 2.5 V controlled by USB FX2 microcontroller (signal FX2_PS_EN)

PS_EN = FX2_PS_EN = 1 or 0

PON (off, open)

(error)

Power rails 1.2 V and 2.5 V always enabled (PS_EN = 1)

PS_ENFX_PS_EN = 1 or 0

...


Signal FX2_PS_EN

To command signal FX2_PS_EN, read the reference firmware code.
IOD = 0x03; // Enable PS_EN and disable PROG_B
OED = 0x03; // Configure PS_EN and PROG as outputs

 

Scroll pdf title
titleTable from EZ-USB(R) Technical Reference Manual

Table from EZ-USB(R) Technical Reference Manual (EZ-USB_TRM.pdf)

Port D Pin
Alternate
Function
Alternate Function
is Selected By...
Alternate Function
is Described in...
PD.7:0FD[15:8]

IFCFG1 = 1 and

any WORDWIIDE bit = 1
Slave FIFOs chapter 9 on page 99

Table from EZ-USB(R) Technical Reference Manual (EZ-USB_TRM.pdf).

Signal PS_EN

  • Signal PS_EN enables (1) or disables (0) power rails 1.2 V and 2.5 V.


    Image Removed
    Figure 36:

    Scroll pdf title
    titlePower rails 1.2 V and 2.5 V could be enabled/disabled by signal PS_EN
    .
    Image Added
  • Power-rail 3.3V is not controlled by signal PS_EN and is unconditionally enabled. 
    Image Removed  
    Figure 37:

    Scroll pdf title
    titlePower rail 3.3 V could not be enabled/disabled by signal PS_EN
    .
    Image Added
    .

VCCIO0 assembly options

According to the corresponding assembly option, power rail VCCCIO0 can depend or not on the power rail 2.5V.

Voltage VccIO for bank B0 shall span from 2.5 V to 3.3 V. VccIO can be supplied either externally or internally to the micromodule.

(warning)
Warning
Warning!

Spartan-3 I/Os are not 5 V tolerant. Applying more than the recommended operating voltages at any pin, results in a damaged FPGA (see Xilinx Answer AR#19146).

Image Removed

Figure 37:
Scroll pdf title
titleexample of VCCIO0 assembly not dependent on power rail 2.5V. The other way is also possible
.
Image Added

Slide Switch S2 = FX2 PON 

When slide switch S2 is in the left position ( = FX2 PON : power rails conditionally on depending on signal FX2_PS_EN), signal PS_EN is set to signal FX2_PS_EN (PS_EN = FX2_PS_EN) driven by the EZ-USB FX2LP USB FX2 microcontroller under user control (IOD and OED of fw.c).

Image Removed Image Removed

...

Scroll pdf title
titleS2 on position FX2 PON (PS_EN = FX2_PS_EN = 1 or 0 )

...

Image Added 

...

Image Added
  1. Dynamic full power operation (PS_EN = 1): when the EZ-USB FX2LP USB FX2 microcontroller sets signal PS_EN = FX2_PS_EN = high, power rails 1.2 V and 2.5 V are enabled.
    This setting can be useful for .
  2. Dynamic low power operation (PS_EN = 0): when the EZ-USB FX2LP USB FX2 microcontroller resets signal PS_EN = FX2_PS_EN = low, the following components are switched off:
    • FPGA core logic (1.2V)
    • DDR SDRAM (2.5V)
    • FPGA bank 3 (2.5V)
    • VREF (2.5V)
    • VCCCIO0 (2.5V) FPGA bank 0 (if R131+R132- assembly)

Slide Switch S2 = PON 

Full power operation (PS_EN = 1): when slide switch S2 is in the right position (PON = power rails unconditionally on), signal PS_EN is set to power rail 3.3V. Thus power rails 1.2 V and 2.5 V are unconditionally enabled.Image Removed Image Removed
Figure 39:

Scroll pdf title
titleS2 on position PON (PS_
EN ≠
EN ≠ FX2_PS_EN = x;
 
PS_EN = high )
 Image AddedImage Added

. 

Summary table

Table 14 The table below summarizes all switching options implied by slide switch S2 and firmware signal FX2_PS_EN (under the standard assembly option).

 

Scroll pdf title
titleSlide switch S2 settings overview ( 1.2 V , 2.5 V, VCCIO0)

power rail

S2= PON
(PS_EN = 1)

(PS_EN ≠ FX2_PS_EN)
(Full power)

S2 = FX2 PON and
PS_EN = FX2_PS_EN = 1

(Dynamic full power)

S2 = FX2 PON and
PS_EN = FX2_PS_EN = 0

(Dynamic low power)

1.2V

on

on

off

2.5V

on

on

off

VCCCIO0 (= 2.5V)
R131+R132- assembly (1)

on

on

off

VCCCIO0 (= 3.3V)
R131-R132+ assembly (2)

on

on

on

(1) R131 populated / R132 unpopulated

(2) R131 unpopulated / R132 populated

Table 40: Slide switch S2 settings overview ( 1.2 V , 2.5 V, VCCIO0).

 Alternate Assembly Options for Slide Switch S2

Slide switch S2 can be replaced by one resistors in the following cases:

...

Assembly option when resistor R17 not populated and R19 populated is equivalent to slide switch S2 permanently set to PON.Image Removed
Figure 41: assembly

Scroll pdf title
titleAssembly option: S2 = PON

...

Image Added

Assembly option when resistor R17 populated and R19 not populated is equivalent to slide switch S2 permanently set to FX2 PON.Image Removed
Figure 42:

Scroll pdf title
titleAssembly option: S2 = FX2 PON

...

...

Image Added

...

Warning

Any other assembly options of R17 and R19 are not allowed.