A total of 110 FPGA user I/Os are available on corresponding contacts of B2B connectors J4 and J5 (see Appendix here).
- 37 differential digital I/O pairs:each pair is configurable as 2 single-ended digital I/Os, corresponding to a maximum of 74 single-ended digital I/Os;
- 4 differential clock input pairs:each pair is configurable as differential digital I/O pair or 2 single-ended clock inputs or 2 single-ended digital I/Os (or combination thereof), corresponding to from a maximum of 8 independent clock inputs to a maximum of 8 independent digital I/Os;
- 1 differential clock input pair:the pair is configurable as differential digital input pair or as 2 single-ended clock inputs or 2 single-ended digital inputs (or combination thereof), corresponding to from a maximum of 2 independent clock inputs to a maximum of 2 independent digital inputs;
- 21 single-ended digital I/Os;
- 5 single-ended inputs.
The table below summarizes the maximum available FPGA user I/Os divided by supply voltage.
Scroll pdf title |
---|
title | Maximum FPGA user I/Os by supply voltage. |
---|
|
type | VccIO | 3.3 V |
---|
diff. I/O pairs | ≤ 18 | ≤ 23 | diff inputs | ≤ 1 | none | diff. clocks | ≤ 4 | ≤ 1 | s. e. I/Os | ≤ 46 | ≤ 58 | s. e. inputs | ≤ 2 | ≤ 4 | s. e. clocks | ≤ 8 | ≤ 3 |
|
Differential signal pairs