Byte
Value
Description
1
0xAA
FLASH_WRITE_COMMAND command ID
2
Write length
Write command length
3
Read length
Read command length
From 4 to write length +3
SPI command(s)
Write SPI command(s)
From write length+4 to 64
-
Not used
From 1 to read length
SPI Data Out sequence
From read length +1 to 64