Scroll Ignore |
---|
Download PDF version of this document.
|
Company | Trenz Electronic GmbH |
---|---|
PCN Number | PCN-JJJJMMDD20231110 |
Title | PCN-JJJJMMDD TEXXXX-XX TitleTE0729-02 to TE0729-03 Hardware Revision Change |
Subject | Hardware Revision Change |
Issue Date | JJJJMMDD2023-12-13 |
This change affects all Trenz Electronic TEXXXX Electronic TE0729 SoMs: TEXXXXTE0729-XX02*.
Affected Product | Replacement | TE | TE|
---|---|---|---|
TE0729-02-62I63MA | TE0729-03-62I63MA | ||
TE0729-02-62I63MAK | TE0729-03-62I63MAK | ||
TE0729-02-62I63MAS | TE0729-03-62I63MAS | ||
TE0729-02-62I65MM | EOL | ||
TE0729-02-62I63MAY | EOL |
...
Type: Schematic Change
Reason: EOL of Component.
Impact: None. Increased current output capability. Minor changes in electrical characteristics.
...
...
Type: Schematic Change
Reason: EOL of Component.
Impact: None. Increased current output capability. Minor changes in electrical characteristics.
...
...
Type: Schematic Change
Reason: BOM Optimization.
Impact: None. Increased current output capability. Minor changes in electrical characteristics.
...
Type: Schematic Change
Reason: Power handling improvement.
Impact: Power supply starts only if voltage rail VIN is in adequate voltage range.
Type: Schematic Change
Reason: EOL of Component.
Impact: None.
...
Type: Schematic Change
Reason: Improve name handlingnaming.
Impact: None.
...
Type: Schematic Change
Reason: Follow AMD and Texas Instruments recommendation.
Impact: Voltage rails start in other orderCheck that the new power-up sequence fits your requirements. Voltage supervisor (U4) enables 1V voltage rail (DCDC U23) via signal EN_Module. 1V DCDC (U23) enables 1.8V voltage rail (DCDC U25) via signal PG_1V0. 1.8V DCDC (U25) enables 2.5V (DCDC U24) and DDR_VDD (DCDC U26) voltage rails via signal PG_1V8. Voltage rail 3.3V (load switch Q1) is logical AND-enabled via power good signal PG_2V5_3V3 from voltage rail 2.5V DCDC (U24) and DDR_VDD DCDC (U26) via diode (D4) and CPLD (U6) signal EN_3V3 via diode (D5).
...
Type: Schematic Change
Reason: Improve power domain handling for signal FPGA_IO.
Impact: None.
...
Type: Schematic Change
Reason: Protect manual reset pin.
Impact: None.
...
Type: Schematic Change
Reason: Improve noise immunity in needed cases.
Impact: None.
Type: Schematic Change
Reason: Improve thermal situation.
Impact: None.
...
Type: Schematic Change
Reason: Improve decoupling.
Impact: None.
...
Type: Schematic Change
Reason: BOM Optimization.
Impact: None. Minor changes in electrical characteristics.
Type: Schematic Change
Reason: BOM Optimization.
Impact: None. Minor changes in electrical characteristics.
...
Type: Schematic Change
Reason: Increase battery input voltage range.
Impact: None. Changes in electrical characteristics.
Type: Schematic Change
Reason: Update revision information.
Impact: None. Firmware reflects it but custom firmware needs to be updated by customer.
...
Type: Schematic Change
Reason: Use standard fiducials.
Impact: None.
...
Type: Schematic Change
Reason: EOL of Component.
Impact: None.
...
Type: PCB Change
Reason: Improve signal monitoringtesting.
Impact: None.
...
Reason: Required for manufacturing.
Impact: None.
...
.
Type: PCB change
Reason: Result of changes above.
Impact: Changed trace length have to be taken into account in existing designs. The trace length for new revision will be available in TE0729 series pinout generator. Please check if change in trace length still matches your requirements. Adaption of carrier may be necessary.
Type: Documentation Update
...
Scroll Pagebreak |
---|
The revision number is visible on the top side of the PCB.
From XXXXXJuly 2024, after old stock is gone. If the new revision is not suitable for your application and still the former revision of the board is needed, please contact us.
...
If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at
phone
national calls: 05741 3200-0
international calls: 0049 5741 3200-0
Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.
...