Hereunder is reported a sample trace of a successful C# executable version execution.

Info

The character/number typed by the user are reported in red

The answer of test console program are reported n blue.

The menu and menu aids are reported in black.

Note
You should run write test (10) before read test (9). Otherwise read test will fail.

TE_USB_FX2 DLL Example 1.0

...

    10 - Write high speed data (FPGA TX)

    0 - Exit

1

The number of card is 1

TE_USB_FX2 DLL Example 1.0

...

    10 - Write high speed data (FPGA TX)

    0 - Exit

3

Module is not connected!

TE_USB_FX2 DLL Example 1.0

...

    10 - Write high speed data (FPGA TX)

    0 - Exit

2

Module is connected!

USBdev <DEVICE>

        FriendlyName="Trenz Electronic USB FX2"

        Manufacturer="Trenz Electronic"

        Product="TE USB FX2"

        SerialNumber="101"

        Configurations="1"

        MaxPacketSize="64"

        VendorID="0B D0"

        ProductID="03 00"

        class="00h"

        SubClass="00h"

        Protocol="00h"

        BcdDevice="00 00"

        BcdUSB="02 00"

        <CONFIGURATION>

                Configuration="0"

                ConfigurationValue="1"

                Attributes="80h"

                Interfaces="1"

                DescriptorType="2"

                DescriptorLength="9"

                TotalLength="60"

                MaxPower="250"

                <INTERFACE>

                        Interface="2"

                        InterfaceNumber="0"

                        AltSetting="0"

                        class="FFh"

                        Subclass="00h"

                        Protocol="0"

                        Endpoints="6"

                        DescriptorType="4"

                        DescriptorLength="9"

                        <ENDPOINT>

                                Type="BULK"

                                Direction="OUT"

                                Address="01h"

                                Attributes="02h"

                                MaxPktSize="64"

                                DescriptorType="5"

                                DescriptorLength="7"

                                Interval="0"

                        </ENDPOINT>

                        <ENDPOINT>

                                Type="BULK"

                                Direction="IN"

                                Address="81h"

                                Attributes="02h"

                                MaxPktSize="64"

                                DescriptorType="5"

                                DescriptorLength="7"

                                Interval="0"

                        </ENDPOINT>

                        <ENDPOINT>

                                Type="BULK"

                                Direction="IN"

                                Address="82h"

                                Attributes="02h"

                                MaxPktSize="512"

                                DescriptorType="5"

                                DescriptorLength="7"

                                Interval="0"

                        </ENDPOINT>

                        <ENDPOINT>

                                Type="BULK"

                                Direction="IN"

                                Address="86h"

                                Attributes="02h"

                                MaxPktSize="512"

                                DescriptorType="5"

                                DescriptorLength="7"

                                Interval="0"

                        </ENDPOINT>

                        <ENDPOINT>

                                Type="BULK"

                                Direction="IN"

                                Address="84h"

                                Attributes="02h"

                                MaxPktSize="512"

                                DescriptorType="5"

                                DescriptorLength="7"

                                Interval="0"

                        </ENDPOINT>

                        <ENDPOINT>

                                Type="BULK"

                                Direction="OUT"

                                Address="08h"

                                Attributes="02h"

                                MaxPktSize="512"

                                DescriptorType="5"

                                DescriptorLength="7"

                                Interval="0"

                        </ENDPOINT>

                </INTERFACE>

        </CONFIGURATION>

</DEVICE>

 

TE_USB_FX2 DLL Example 1.0

...

    10 - Write high speed data (FPGA TX)

    0 - Exit

5

Major version: 3

Minor version: 2

Device hi: 1

Device lo: 1

TE_USB_FX2 DLL Example 1.0

...

    10 - Write high speed data (FPGA TX)

    0 - Exit

6

Major version: 8

Minor version: 2

Release version: 0

Build version: 0

TE_USB_FX2 DLL Example 1.0

...

    10 - Write high speed data (FPGA TX)

    0 - Exit

7

EP2 FIFO CS: 04

EP4 FIFO CS: 04

EP6 FIFO CS: 28

EP8 FIFO CS: 04

TE_USB_FX2 DLL Example 1.0

...

    10 - Write high speed data (FPGA TX)

    0 - Exit

8

Resetting all FIFOs

TE_USB_FX2 DLL Example 1.0

...

    10 - Write high speed data (FPGA TX)

    0 - Exit

10

Write the Buffer Size desired for EP8

Value suggested is 102400, do not use 131072

102400

Write the Packets Number desired

...

Value suggested is  600 if you are testing TE0300

1200

Write the Packet Length desired

...

in this case you are only able to test write data integrity

 

102400

Write the Timeout value desired, the integer is measured in milliseconds

...

20,50,200,1000 ms (it depends on how much the computer lack real time behavior).

 

1000

You want make an integrity test on data writen on FPGA?

1 for YES, 0 for NO

1

Resetting all FIFOs

TimeSpan 00:00:04.8333753

TimeSpan Minutes 0

TimeSpan Seconds 5

TimeSpan MilliSeconds 833

Millisecond 5833

host->memory  data verification Integrity PASSED!!!

Transferred 120000 kB in 4833 ms = 25.16 MB/s

Resetting all FIFOs

TE_USB_FX2 DLL Example 1.0

...

    10 - Write high speed data (FPGA TX)

    0 - Exit

9

Write the Buffer Size desired for EP6

Value suggested is 102400, do not use 131072

102400

BufferSizeR 102400

Write the Packets Number desired

...

Value suggested is  600 if you are testing TE0300

1200

PacketsNumberR 1200

Write the Packet Length desired

...

you must use 1024 or more for Packet Size value

102400

PacketLengthR 102400

Write the Timeout value desired, the integer is measured in milliseconds

...

20,50,200,1000 ms (it depends on how much the computer lack real time behavior). 

1000

Resetting all FIFOs

 Errors Errors 0

TimeSpan 00:00:03.2986599

TimeSpan Seconds 3

TimeSpan MilliSeconds 298

Millisecond 3298

memory->host data verification PASSED!!!

Transferred 120000 kB in 3298 ms = 35.53 MB/s

Resetting all FIFOs

TE_USB_FX2 DLL Example 1.0

...

    10 - Write high speed data (FPGA TX)

    0 - Exit 

0

With this command the Windows Console will close.