Page History
Scroll Ignore |
---|
Download PDF version of this document. |
Company | Trenz Electronic GmbH |
---|---|
PCN Number | PCN-20230616 |
Title | TE0741-04 to TE0741-05 Hardware Revision Change |
Subject | Hardware Revision Change |
Issue Date | 2023-0706-0127 |
Products Affected
This change affects all Trenz Electronic TE0741 SoMs: TE0741-04*.
Affected Product | Replacement |
---|---|
TE0741-04-A2C-1-A | TE0741-05-A2C-1-A |
TE0741-04-A2I-1-A | TE0741-05-A2I-1-A |
TE0741-04-B2C-1-AF | TE0741-05-B2C-1-AF |
TE0741-04-B2C-1-A | TE0741-05-B2C-1-A |
TE0741-04-B2I-1-A | TE0741-05-B2I-1-A |
TE0741-04-D2C-1-A | TE0741-05-D2C-1-A |
TE0741-04-D2I-1-A | TE0741-05-D2I-1-A |
TE0741-04-G2C-1-A | TE0741-05-G2C-1-A |
TE0741-04-G2I-1-A | TE0741-05-G2I-1-A |
TE0741-04-B3E-1-AF | - |
Changes
#1 Added pull-up resistor
...
R34 for signal net "EN1".
Type: Schematic Change
Reason: Remove floating signal situation.
...
Reason: Remove floating signal situations and enable signal measurementdetection by CPLD.
Impact: None. Firmware reflects it but custom firmware needs to be updated by customer.
...
Impact: Changed trace length have to be taken into account in existing designs. The trace length for new revision shall will be available in 4x5 series pinout generator. Please check if change in trace length still matches your requirements. Adaption of carrier may be necessary.
...