To configure a TE0320 TE USB FX2 module via USB bus, there are different procedures to follow according to module status and purpose of use. For instance, a full quality control test already performed at Trenz Electronic laboratory premises requires all the following steps to be performed:
- Cypress USB generic device driver installation
- USB FX2 microcontroller large EEPROM programming
- specific USB device driver installation
- an *.iic file generation
a firmware upgrade tool (Cypress tools: CyConsole or CyControlCenter TE tools: OpenFut, OpenFutNet or FX2EEPROMProgrammer) utilization.a bitsteam upgade
Scroll pdf title |
---|
title | Configuration steps via USB bus according to module status and purpose of use. |
---|
|
step | first development cycle | following development cycles | EEPROM recovery (boot recovery) | quality control (lab test) | (1) | | | â— | â— | (2) | | | â— | â— | (3) | â— | | | â— | (4) | â— | â— | | â— | (5) | â— | â— | | â— |
Table 24: |
configuration steps via USB bus according to module status and purpose of use.