Note | |||||
---|---|---|---|---|---|
| |||||
If the EP6's buffer is not is not properly written by the FPGA(reference design)/other(custom design) the EP6's buffer will become empty and the host computer will be no longer able to receive further packets. In this case the TE_USB_FX2_GetData() function could experience strange behaviors. For example, a very low throughput (9-10 Mbyte/s even if a 31-38 Mbyte/s are expected) could be measured or the function TE_USB_FX2_GetData() fails returning false. During USB read transmission test (RX: host computer perspective) the EP6's buffer writing is carried out by MicroBlaze (inside the FPGA); this behavior is setted by MicroBlaze API command FX22MB_REG0_START_TX (TX: USB FX2 microcontroller perspective)
|
The maximum data throughput expected (with a DataReadLength= 120*10^6) is 38 Mbyte/s (PacketSize = BufferSize = 102400), but in fact this value is variable between 31-38 Mbyte/s (the mean value seems 33.5 Mbyte/s); so if you measure this range of values, the data reception can be considered as normal.
Note |
---|
The data throughput is variable in two ways:
|
...