Note |
---|
The second driver could be used but it is not recommended because two PIDs are possible. Same VID and two different PIDs are possible (written in the corresponding .inf file):
|
WinUSB driver and Zadig should be used only if libusb or libusbx are the libraries used (instead of Cypress libraries (CyAPI.lib and CyUSB.dll) and the derived Trenz Electronic libraries (TE_USB_FX2_CyAPI.dll and TE_USB_FX2_CyUSB.dll)) by the user under Windows OS.
See WinUSB driver installation (libusb and libusbx). See also Zadig.
Note |
---|
If libusb or libusbx are used (with WinUSB driver and/or Zadig), the software tools Cypress USB Console, Cypress USB Control Center , Python Open_FUT (Gen2), Python Open_FUT (Gen 3) and C# OpenFutNet could not be directly used. The code of these tools should be rewritten using libusb or libusbx instead of Cypress libraries (CyAPI.lib and CyUSB.dll) and the derived Trenz Electronic libraries (TE_USB_FX2_CyAPI.dll and TE_USB_FX2_CyUSB.dll). See as a starting point for a new software tool using libusb or libusbx under Windows OS. |