Reason: Set reset threshold for U26 to 0.904 V.

Impact: None., improved reset behaviour

#13 Added power supervisor BD39040MUF (U27)

Type: Schematic Change

Reason: Improve the Improved voltage rail supervision.

Impact: None. All power rails are now monitored.

#14 Connect BD39040MUF "PG_All" - signal U27.15 to system controller U19.C12 with pull-up resistor R67.

...

Reason: Power Supervisor connection.

Impact: None. Check your If custom CPLD design used, check for compatibility.

#15 Connect BD39040MUF watchdog to CPLD ("WDEN" - signal U27.13 to system controller U19.C6 with pull-down resistor R80

...

Type: Schematic Change

Reason: Power Supervisor connection.

Impact: None. Check your CPLD design for compatibility.

...

, "WDIN" - signal U27.14 to system controller U19.N8

...

Type: Schematic Change

Reason: Power Supervisor connection.

Impact: None. Check your CPLD design for compatibility.

...

"WDOUT" - signal U27.16 to system controller U19.M3).

Type: Schematic Change

Reason: Power Supervisor connectionWatchDog connected for possible future use to CPLD.

Impact: None. Check your WatchDog connected for custom use to CPLD. If custom CPLD design used, check for compatibility.

#18 Signal MIO8 (U5.E5) connected to system controller (U19.N7).

...

Reason: Enable boundary scan for MIO bank 1.

Impact: None. Check your If custom CPLD design used, check for compatibility.

#19 Added pull-down resistors R64 for net "ON_1V0".

...

The model code and revision number of the module "TE0720-04" are printed on the top side of the PCB for revision 04.