Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Affected Product

Replacement
TE0725-03-15-1CTE0725-04-21C-1-A
TE0725-03-35-2CTE0725-04-42C-1-A
TE0725-03-100-2CTE0725-04-72C-1-A
TE0725-03-100-2CFTE0725-04-72C-1-F
TE0725-03-100-2I9TE0725-04-72I-1-B

(ED: Tabelle ist fertig.)

Changes

#1 Changed DCDC EN5311QI (U11) to MPM3834CGPA (U5) and adapted power circuit.

...

#4 Changed HyperRAM (U4) from S27KS0641DPBHI000 to IS66WVH8M8FALL-166B1LI.

Type: BOM change

Reason: HyperRAM improvement EOL of component.

Impact:None  Custom design needs to be updated by customer.

#5 Changed clock (U3) from SiT8008AI-73-XXS-100.000000E to SiT8008BI-73-XXS-100.000000E.

...

#10 Set resistor (R13) to not fitted.

Type: BOM Change

Reason: BOM Optimization Resistor is not needed due to new diode.

Impact: None.

#11 Changed inductor (L1, L2, L3, L4, L6) from BKP0603HS121-T to MPZ0603S121HT000.

...