Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

...

  • Shop TE0808-Starter-Kit - contains prices, order number, content... contains prices, available stock, disposability, scope of delivery and more

Xilinx Software and Driver


Additional Documentation

Table of Contents

Important Notes

Warning
Do not change XMOD DIP-Switch settings on TEBF0808. Do not swap the XMOD adapters the one marked with green dot must be closer to the SoM

...

Note

For all Starter Kit's shipped before 2017-06-21:

Enclosure Power and HD LED was swapped on connector. See "Enclosure Power Button, Reset Button, HDD LED and Power LED"  section for correct connection.

Getting Started

Starter Kit is shipped with prebuilt Linux Example on SD. Newest version and sources are available on our download area: TE0808 Reference Designs

  1. Connect main power and set power switch to on. See Main Power Enclosure Location

  2. Connect mini USB cable from XMOD with green dot to host PC. See XMODs Connection
  3. Insert SD-Card with pre-loaded content into SD-Card slot.
  4. Open Serial Console:
    1. COM Port: for correct number see device manager
    2. Speed:115200
  5. Press the Power on button on the enclosure. See Power Button, Reset Button, HDD LED and Power LED Enclosure Location
  6. Linux login:
    1. User Name:root
    2. Password:root

Starter Kit Basic

Main Power Enclosure Location

Power Button , Reset Button, HDD LED and Power LED Enclosure  Location

 


Warning
 Do not change XMOD DIP-Switch settings on TEBF0808. Do not swap the XMOD adapters the one marked with green dot must be closer to the SoM

...

- Section is currently not complete -

Main Power Switch is OFF

No Power on Starter Kit.

Identification: FANs do not work, all LEDs are off.

Main Power Switch is ON and Power Button is not pressed

Only some basics on TEBF0808 are powered on. This mode is used for CPLDs Firmware updates.

Identification: FANs do not work, some LEDs blinking.

LED description(need CPLD Firmware REV06 or newer):

...

Indicate board is powered off.

...

RGPIO 14 and 15, if RGPIO is active.

...

MIO40, if RGPIO is deactivated

Main Power Switch is ON and Power Button is pressed first time

TE0808 will be powered on. System boots if boot mode is set correct and files are available.

Identification: FANs do work, LEDs blinking states change.

LED description (need CPLD Firmware REV06 or newer):

...

Indicate board is powered off.

...

RGPIO 14 and 15, if RGPIO is active.

...

MIO40, if RGPIO is deactivated

...

Indicates the PS is not initialized after a power-on reset (POR).

...

The PS_ERROR_OUT signal is asserted for accidental loss of power, an error, or an exception in the PMU.

...

The PS_ERROR_STATUS indicates a secure lockdown state. Alternatively, it can be used by the PMU firmware to indicate system status.

...

RGPIO 16 and 17, if RGPIO is active

...

SI5345 NVM on the module is not programmed on factory, so modified FSBL is needed to get running output CLKS.

It is possible to program NVM of the SI5345 2 times, see Si5345

Notes

Most LEDs are CPLD Firmware dependents, see TEBF0808 Master CPLD and TEBF0808 Slave CPLD

Starter Kit will be shipped with all cable connected.

ATX Power

Module

FMC FAN

XMODs

Enclosure USB

Enclosure FAN1 and HDAUDIO

Enclosure Power Button , Reset Button, HDD LED and Power LED

Support