The Trenz Electronic TE0725 is a low cost small-sized FPGA module integrating a Xilinx Artix-7 (15-100T) and 32 MByte Flash memory for configuration and operation.
Block Diagram
Page break |
---|
Main Components
...
When using XMOD-JTAG please check the switch settings on XMOD to be sure the power and I/O reference are supplied correctly. TE0790 can be in some case be cases used to power up TE0725, however this is however not recommended. TE0790-01 has can not supply enough power for TE0725 (LED Blink may work, for larger designs the XMOD delivered power may be not sufficientmay blink but the module is not operating properly, especially in case of larger and more sophisticated designs).
LED's
LED | Color | FPGA | Notes |
---|---|---|---|
D2 | green | M16 | |
D3 | red | DONE | Active Low |
...
Parameter | Min | Max | Units | Notes | Reference document |
---|---|---|---|---|---|
Vin VIN supply voltage | -0.1 | 3.6 | V | ||
I/O Bank supply voltage | -0.5 | 3.6 | V | Xilinx document DS181 | |
I/O input voltage for FPGA I/O banks | -0.4 | VCCO_X+0.55 | V | Xilinx document DS181 | |
GT Transceiver | -0.5 | 1.26 | V | Xilinx document DS181 | |
Voltage on Module JTAG pins | -0.4 | VCCO_0+0.55 | V | VCCO_0 is 1.8V or 3.3V nominal | Xilinx document DS181 |
Storage Temperature | -40 | +85 | C |
...
Parameter | Min | Max | Units | Notes | Reference document |
---|---|---|---|---|---|
Vin VIN supply voltage | 3.135 | 3.45 | V | ||
IO Bank supply voltage for I/O banks | 1.14 | 3.465 | V | Xilinx document DS181 | |
I/O input voltage for I/O banks | -0.20 | VCCO + 0.20 | V | Xilinx document DS181 | |
Voltage on Module JTAG pins | 3.135 | 3.465 | V | For assembly variant with 3.3V CONFIG Bank Option | Xilinx document DS181 |
...
Please note that two different units are used on the figures below, SI system millimetersmillimeter(mm) and imperial system thousandth of an inch(mil). This is because of the 100mil pin headers used, see also explanation below. To convert mil's to millimeters and vise vice versa use formula 100mil's = 2,54mm.
...
All parts are at least commercial temperature range of 0°C to +70°C. The module operating temperature range depends on customer design and cooling solution. Please contact us for options.
Industrial grade modules
All parts are at least industrial temperature range of -40°C to +85°C.
The module operating temperature range depends on customer design and cooling solution. Please contact us for options.
...
Date | Revision | Notes | PCN | Documentation link |
---|---|---|---|---|
- | 01 | Prototypes | ||
- | 02 | First production release | TE0725 TRM | |
2016-12-09 | 03 | Second production release | Click to see PCN |
Hardware revision number is printed on the PCB board together with the module model number separated by the dash.
...
Date | Revision | Contributors | Description |
---|---|---|---|
2016-12-09 | Hardware REV03 specific information added | ||
2016-12-09 | V40 | Hardware REV02 Rev02 Block Diagram added | |
2016-12-02 | V1
| Initial version |
...