Key Features
- Motor control evaluation with an suitable controller board
- Quick evaluation with reference motor board
- Power option up to 48V and 30A main supply current
...
Detail | Option 1: Reference Motor Board with DC +12V Supply | Option 2: Customer Motor at individual DC +5..48V | Comments |
---|---|---|---|
Motor Supply | From DC +12V Input J7 via Fuse F3 (TODO ... A) | From customer DC Supply to J6 via F1 on Drive Boad | |
Motor Connection | Motor wires connected to cage clamps on Motor Reference Board J5 (A), J4 (B), J3 (C) | Motor wires connected to bolt screw terminals on Drive Board J2 (A), J3 (B), J4 (C) | |
Encoder Connection Single Ended | From encoder pins via 6Pin PMoD to Drive Board J10: J10 single ended:Pin 1: GND | From motor to Drive Board to J11 (single/differential): J11 single ended:Pin 2: +5V Supply | Jumper Settings for encoder signals.
|
Encoder Connection Differential | J11 differential with 100R terminated: Pin 2: +5V Supply Pin 3: GND Pin 5: ENC A negativ Pin 6: ENC A positiv Pin 7: ENC B negativ Pin 8: ENC B positiv Pin 9: ENC I negativ Pin 10: ENC I positiv |
...
Onboard is a Maxim 1-Wire Temperature sensor DS18S20Z+. This sensor is located in the middle of the PCB.
Addional 1-Wire sensor(s) can be connected to the connector J16:
- Pin 1(DQ), 3 (GND),5 (+3.3V) at the same 1-wire bus as the onboard one
- Pin 2(DQ), 4 (GND),6 (+3.3V) at a separate 1-wire bus
...
- only allowed to be used for electrical specialist for the used electrical voltage and power conditions
- only allowed to be used under electrical laboratory conditions
- only allowed to be used in horizontal position on a non-conducting and non-inflammable surface
- only allowed to be used with a wiring, which fulfills the current rating for the maximum possible currents.
- only allowed to be used with a suitable current limiting circuit
- The maximum continuous current must not exceed 30A.
- The delivered fuse "Littelfuse Tpye 142.5631.5302" must be used as current limiter between connector J5 and J6.
- To limit the current for smaller motor loads an ADDITIONALLY appropriate current limiter can be used e.g. a current limited power source or a fuse integrated in the wiring.
- only allowed to be used with appropriate connectors at the M5 screw connectors, which means M5 cable lugs must be used and fastened according to technical standards.
- only allowed to be used, if the "Drive Boad high current signals" conducting up to 30A nominal, are covered by isolating, mechanically stable, non-inflammable (UL V-1 or better) material
The "Drive Board high current signals" are the motor outputs A, B, C and Fuse F1 Connectors J5 an J6 and further internal connections shown white marked in the following picture:
- As minimum protection it is mandatory to use the delivered "Isolating cover PCB" (marked in green), which must be mounted to the mounting holes H1, H9, H3, H4 with the delivered 10mm isolating spacers:
Board with isolating cover - front view
Board with isolating cover - side view - The used cable lugs need to be isolated in the area outstanding the outer border of the Drive Board.
Make sure that the "Isolating Cover PCB" is overlapping the conducting material by a minimum of 20 mm.
...