Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

In this demo the general approach on how to communicate with the module and perform high speed measurements with
the ADC are shown.

Communicating with module:

To communicate with the module, a serial comport port with a speed set to 115200 bits needs to be opened.
Commands consists of a single  character in UTF-8 encoding.
It is good practice to communication with the module following these steps:

...

These steps apply also for read operations.

Using the ADC for high speed consecutive measurements

The module provides a method to gather highly accurate consecutive ADC measurements in a single event.
In this mode of operation, one mega sample of ADC values are performed and stored inside the modules
SD-RAM.

...

Information to convert the RAW ADC data into standard integer values.

Module TEI0015 - AD4003BCPZ-RL7

Resolution: 18-bit / 5 nibbles
Maximum sampling rate: 2 MSPS

...


HexDec
HexDec
Mid scale0x000000


Positive 1 LSB0x000011to full scale -1 LSB0x1ffff131071
Negative full scale0x20000131072to -1 LSB0x3FFFF262143

Module TEI0016 - ADAQ7988BCCZ

Resolution: 16-bit / 4 nibbles
Maximum sampling rate: 0.5 MSPS

...