Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...


ETHSD CardUSB HostResetUser LEDsUSB UARTUSB JTAG
TE0710(question)(Stern), 3.3V B16 I/O(error)(tick)(star), 2 LEDs(tick)(tick)
TE0711(error)(star), 1.8V B16 I/O(error)(tick)(question)(tick)(tick)
TE0712(star), 100 MBit(star), 1.8V B13 I/O(error)(tick)(question)(tick)(tick)
TE0713(error)(star), 1.8V B13 I/O(error)(tick)(question)(tick)(tick)
TE0715-15(tick)(tick)(tick)(tick)(question)(tick)(tick)
TE0715-30 (warning)(2)(tick)(tick)(tick)(tick)(question)(tick)(tick)
TE0720(tick)(tick)(tick)(tick)(question)(tick)(tick)
TE0741 (warning)(4)(error)(error), MGTs(error)(tick)(question)(tick)(tick)
TE0820 (warning)(2)(tick)(Haken)(6)(tick)(question)(question)(tick)(tick)
TE0841 (warning)(2)(3)(error)(error), MGTs(error)(tick)(question)(tick)(tick)
  • (2) HP IO Banks only support 1.8V
  • (3) MGT's Lanes connected to SD-Level shifter: TE0703-06: Leave J11 open; TE0703-05 and before: It's recommended to desolder level shifter.
  • (4) MGT's Lanes connected to SD-Level shifter, but module side 1.8V is not connected.
  • (6) REV06 select correct SDIO voltage by jumper J11. REV05 and before: Works, but without carrier board modification out of specification (TE0703 SD Levelshifter powered fix by 1.8V, TE0820 SD MIO-Bank by 3.3V).

...


ETH1ETH2SD CardUSB Host
TE0710(question)(question)(Stern), 3.3V B16 I/O(error)
TE0711(error)(question)(star), 1.8V B16 I/O(error)
TE0712100 MBit(question)(star), 1.8V B13 I/O(error)
TE0713(error)(question)(question)(error)
TE0715-15(tick)(tick)(tick)(tick)
TE0715-30 (warning)(2)(tick)(tick)(tick)(tick)
TE0720(tick)(tick)(tick)(tick)
TE0741 (warning)(4)(error)(question)(error), MGTs(error)
TE0820 (warning)(2)(tick)(question)(Haken)(6)(tick)
TE0841 (warning)(2)(3)(error)(question)(error), MGTs(error)
  • (2) HP IO Banks only support 1.8V
  • (3) MGT's Lanes connected to SD-Level shifter: TE0703-06: Leave J11 open; TE0703-05 and before: It's recommended to desolder level shifter.
  • (4) MGT's Lanes connected to SD-Level shifter, but module side 1.8V is not connected.
  • (6) REV06 select correct SDIO voltage by jumper J11. REV05 and before: Works, but without carrier board modification out of specification (TE0703 SD Levelshifter powered fix by 1.8V, TE0820 SD MIO-Bank by 3.3V).

...

  • TEBA0841 has no dedicated power plug connector for 3.3V main power. External Power Supply must be connected to  J17, J20, J4 or J3 3.3V Pin. Do not use XMOD for power supply.
  • TEBA0841-REV01 VCCIOB and VCCIOC are not connected.
  • (6) Works, but without carrier board modification out of specification: TE0706 SD Levelshifter powered fix by 1.8V, TE0820 SD MIO-Bank by 3.3V.
  • (7) SD signals only, no SD-Card connector
  • (8) CLK not connected on TE0710
  • (9) Check schematics  or TE Master Pinout Excel Sheet for detailed connection and IO Bank power supply
  • (10) With TEBA0841-01 is Boot Mode not selectable, please contact Trenz Electronic Support, if you need a Zynq or ZynqMP Module with TEBA0841-1. With TEBA0841-2 it's usable.
  • (11) MGT polarity is swapped


TEF1002


FMCFMC VadjSFPSATAPCIeUSB HostSD Card

EthernetFFA & FFB
TE0710(Frage)
(Frage)
(Frage)
(Frage)
(Frage)
(Fehler)
(Frage)
, 3.3V B16 I/O(Frage)
(Frage)
TE0711(Frage)
(Frage)
(Frage)
(Frage)
(Frage)
(Fehler)
(Frage)
, 1.8V B16 I/O(Frage)
(Frage)
TE0712(Frage)
(Frage)
(Haken)
Frage
(Frage)
(Frage)
(Frage)
(Fehler)
(Frage)
, 1.8V B13 I/O(Haken)
(Frage)
TE0713(Frage)
(Frage)
(Frage)
(Frage)
(Frage)
(Fehler)
(Frage)
, 1.8V B13 I/O(Frage)
(Frage)
TE0715 (Frage)
(Frage)
(Frage)
(Frage)
(Frage)
(Frage)
(Frage)
(Frage)
(Frage)
TE0715-30 (Frage)
(Frage)
, Max 1.8V(Frage)
(Frage)
(Frage)
(Frage)
(Frage)
(Frage)
(Frage)
(Frage)

TE0720 

(

Frage

12)

(Frage)(Haken)
Frage
(Frage)
(Frage)
(Frage)
(Haken)
(Haken)
(Haken)
(Frage)

TE0741

(Frage)
(Frage)
(Frage)
(Frage)
(Frage)
(Fehler)
(Fehler)
,MGTs(Frage)
(Frage)
(Frage)
TE0820
(
Frage
13)(Frage)(Stern)
Frage
, Max 1.8V(Frage)
(Frage)
(Frage)
(Haken)
(Haken)
(Haken)
(Frage)
TE0841(Frage)
(Frage)
(Frage)
(Frage)
(Frage)
(Fehler)
(Fehler)
,MGTs(Frage)(Frage)


  • (

...

  • 12) FMC_VADJ powers VCCIOC connected to power input of Bank 34 VCCO34 on TE0720. In standard Firmware dip S3-2 can be used to switch ON FMC_VADJ without FMC installed. 
  • (13) FMC_VADJ powers VCCIOC connected to power input of Bank 65 VCCO_65 on TE0820. In standard Firmware dip S3-2 can be used to switch ON FMC_VADJ without FMC installed. Select max 1.8V (HP bank)!

...