Software which needs to be installed prior to configure the module.
For changing the FTDI configuration:

...

For ,
for programming the FPGA Intel MAX 10: 

...

The compressed folder needs to be extracted, so that they the contend can be used inside other programs.
Arrow-USB-Blaster and Quartus prime need to be installed to update the firmware,
Visual Analog for running the demo.

...

  1. Figure out the modules COM port number
    1. Open the device manager, right click onto windows start menu symbol and select device manager
    2. Open ports and identify the port used by the module, the number is here marked with an X

      Scroll Title
      anchorFigure 1


      Scroll Ignore

      draw.io Diagram
      bordertrue
      viewerToolbartrue
      fitWindowfalse
      diagramDisplayName
      lboxtrue
      revision5
      diagramNameTEI0015_data_capture-demo_Visual-Analog_device-manager
      simpleViewertrue
      width
      linksauto
      tbstyletop
      diagramWidth542


      Scroll Only



  2. Setup Visual Analog
    1. Start Visual Analog and open a Blank canvas

      Scroll Title
      anchorFigure 1


      Scroll Ignore

      draw.io Diagram
      bordertrue
      viewerToolbartrue
      fitWindowfalse
      diagramDisplayName
      lboxtrue
      revision2
      diagramNameTEI0015_data_capture-demo_Visual-Analog_open
      simpleViewertrue
      width
      linksauto
      tbstyletop
      diagramWidth575


      Scroll Only



      Via File → Open point to the file AnalogMAX_DAQ1_Capture.vac from the demo folder.

      Scroll Title
      anchorFigure 1


      Scroll Ignore

      draw.io Diagram
      bordertrue
      viewerToolbartrue
      fitWindowfalse
      diagramDisplayName
      lboxtrue
      revision2
      diagramNameTEI0015_data_capture-demo_Visual-Analog_blanc-canvas
      simpleViewertrue
      width
      linksauto
      tbstyletop
      diagramWidth643


      Scroll Only



    2. Press Tools → External Tools... to prepare the usage of adcapture.exe, in the new appearing window

      Scroll Title
      anchorFigure 1


      Scroll Ignore

      draw.io Diagram
      bordertrue
      viewerToolbartrue
      fitWindowfalse
      diagramDisplayName
      lboxtrue
      revision2
      diagramNameTEI0015_data_capture-demo_Visual-Analog_Capture.vac
      simpleViewertrue
      width600
      linksauto
      tbstyletop
      diagramWidth636


      Scroll Only



    3. Click Add in the new opened window and insert the name "adcapture" in the Display Text.
      Click Browse... and select the file "adcapture.exe" from the downloaded demo.
      Into Arguments insert "COMX,115200 1024 c:\temp\capture.txt 7", where the X in COMX
      is a placeholder for your comport number.

      To finish the setup press OK.

      Scroll Title
      anchorFigure 1


      Scroll Ignore

      draw.io Diagram
      bordertrue
      viewerToolbartrue
      fitWindowfalse
      diagramDisplayName
      lboxtrue
      revision4
      diagramNameTEI0015_data_capture-demo_Visual-Analog_adcapture-setup
      simpleViewertrue
      width
      linksauto
      tbstyletop
      diagramWidth445


      Scroll Only


      Parameter description:
      COM14 - COM port which is used for the connection.
      115200 - Baud rate which is used for the connection.
      1024 - Amount of K samples to read, minimum 64 and maximum is 1024.
      c:\temp\capture.txt - File name and path which specifies where to storage the data.
      7 - Command to adjust the gain, possible values are:
                 4 1 for a gain of 1, 5 2 for a gain of 2, 6 4 for a gain of 4 and 7 8 for a gain of 8

  3. Launch adcapture
    1. To run the demo, select the above inserted tool by selecting Tools → adcapture, a new window opens
    2. The window shows the activity of the tool "adcapture", the picture below shows its state when it is finished

      Scroll Title
      anchorFigure 1


      Scroll Ignore

      draw.io Diagram
      bordertrue
      viewerToolbartrue
      fitWindowfalse
      diagramDisplayName
      lboxtrue
      revision3
      diagramNameTEI0015_data_capture-demo_Visual-Analog_adcapture-run
      simpleViewertrue
      width
      linksauto
      tbstyletop
      diagramWidth746


      Scroll Only



    3. In Visual Analog, use "F5" or press Canvas → Run to update the screen

      Scroll Title
      anchorFigure 1


      Scroll Ignore

      draw.io Diagram
      bordertrue
      viewerToolbartrue
      fitWindowfalse
      diagramDisplayName
      lboxtrue
      revision1
      diagramNameTEI0015_data_capture-demo_Visual-Analog_window-demo-run
      simpleViewertrue
      width600
      linksauto
      tbstyletop
      diagramWidth1921