CompanyTrenz Electronic GmbH
PCN NumberPCN-20231006
TitleTE0630-02 to TE0630-03 Hardware Revision Change
SubjectHardware Revision Change
Issue Date

2023-11-01

Products Affected

This change affects all Trenz Electronic TE0630 SoMs: TE0630-02*.

Affected Product

Replacement
TETE

Changes

#1

Type:

Reason: 

Impact:

#2 Changed DCDC EN6347QI (U7) to MPM3860GQW-Z and adapted power circuit.

Type: Schematic Change

Reason: EOL of Component.

Impact: None. Increased current output capability. Minor changes in electrical characteristics.

#2 Changed DCDC EN6338QI (U5, U8) to MPM3834CGPA and adapted power circuit.

Type: Schematic Change

Reason: EOL of Component.

Impact: None. Increased current output capability. Minor changes in electrical characteristics. (Needs to be checked!!!).


#10 Added pull-up resistor (R84) for clock U10 enable signal.

Type: Schematic Change

Reason: Follow clock enable recommendation.

Impact: None.

#10 Added optional pull-down resistor (R70) to add pull-down option for function "HSWAPEN".

Type: Schematic Change

Reason: Enable "HSWAPEN" pull-down option.

Impact: None.

#10 Added pull-up resistor (R85) for clock U11 enable signal.

Type: Schematic Change

Reason: Follow clock enable recommendation.

Impact: None.

#9 Changed resistor (R46) from 2.2 kOhm to 470 Ohm.

Type: Schematic Change

Reason: Follow AMD recommendation. ???

Impact: None.

#11 Board revision coding updated to REV03.

Type: Schematic Change

Reason: New revision

Impact: If hardware coding of board revision is used in design, update is needed.

#11 Board variant coding updated to REV03 variants.

Type: Schematic Change

Reason: New revision

Impact: If hardware coding of board revision is used in design, update is needed.

#12 Changed 22 µF capacitor (C77, C80) from 6.3 V to 10 V.

Type: Schematic Change

Reason: BOM Optimization.

Impact: None.

#18 Removed serial number S/N.

Type: Schematic Change

Reason: EOL of Component.

Impact: None.

#17 Changed fiducials to standard fiducial type.

Type: Schematic Change

Reason: Use standard fiducials.

Impact: None.

#18 Removed TE logo.

Type: Schematic Change

Reason: Result of changes above.

Impact: None.

#18 Removed testpoints (TP2, TP3, TP7, TP10, TP13, TP14, TP15, TP17, TP19, TP20, TP21, TP27, TP28, TP30, TP31, TP32). ?????

Type: Schematic Change

Reason: Result of changes above. ???????

Impact: None.

#18 Added testpoints (TP27, TP28). ?????

Type: Schematic Change

Reason: Result of changes above. ???????

Impact: None.

#15 Added UKCA logo.

Type: PCB Change

Reason: Required for export to UK.

Impact: None.

#19 Updated components from library.

Type: Schematic Change

Reason: Use latest component data.

Impact: None.

#18 Updated group tables and colours on "B2B_Connector" page.

Type: Documentation Update

Reason: Documentation improvement.

Impact: None.

#20 Updated legal notices, revision history, block and power diagram. Updated page count and order. 

Type: Documentation Update

Reason: Documentation improvement.

Impact: None.

Method of Identification



Production Shipment Schedule

From XXXXX, after old stock is gone. If the new revision is not suitable for your application and still the former revision of the board is needed, please contact us.


Contact Information

If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at

Disclaimer

Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances.  For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.