Company | Trenz Electronic GmbH |
---|---|
PCN Number | PCN-20240909 |
Title | TE0865 CPLD Firmware update and its consequences for interconnecting with TEBT0865-01 |
Subject | TE0865 CPLD Firmware patch and consequences for carrier board TEBT0865-01 |
Issue Date | 2024-09-02 |
Products Affected
This change affects all Trenz Electronic TEBT0865-01 with a serial number greater than 860651 and all TE0865-02 with CPLD firmware REV03. Refer to for CPLD firmware identification. (Link einfügen)
Changes
#1 CPLD Firmware Update for TE0865-02 and hardware modification for carrier board TEBT0865-01.
Type: Firmware Update
Reason: Improve firmware.
Impact: Updated firmware leads to bring-up problems with old carrier board TEBT0865-01. Therefore, a hardware patch is applied for TEBT0865-01 with a serial number greater than 860651.
Patch description:
Manual Firmware Update
Firmware Revision Checking: Follow instructions on page TE0865 CPLD Firmware to figure out which firmware revision your TE0865 is using and/or to
Method of Identification
Production Shipment Schedule
From XXXXX, after old stock is gone. If the new revision is not suitable for your application and still the former revision of the board is needed, please contact us.
Contact Information
If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at
- forum.trenz-electronic.de
- wiki.trenz-electronic.de
- support%trenz-electronic.de (subject = PCN-JJJJMMDD)
phone
national calls: 05741 3200-0
international calls: 0049 5741 3200-0
Disclaimer
Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.
This PCN follows JEDEC Standard J-STD-046.