Compressed folder, containing all necessary files for the demo - Download-Link
The compressed folder needs to be extracted, so that the contend can be used inside other programs.
The demo itself requires the installation of Visual Analog (Version 1.9.48.1) - Download Link Open ports and identify the port used by the module, the number is here marked with an X Start Visual Analog and open a Blank canvas Press Tools → External Tools... to prepare the usage of adcapture.exe, in the new appearing window Click Add in the new opened window and insert the name "adcapture" in the Display Text. To finish the setup press OK. Parameter description: Befor running the demo, in Visual Analog, fill into the Pattern Loader the ADC sampling rate of your module: The window shows the activity of the tool "adcapture", the picture below shows it, when it is finished In Visual Analog, use "F5" or press Canvas → Run to update the screen Open ports and identify the port used by the AnalogMAX DAQ1 as visible in Figure 10.Setting up Visual Analog and running the data capture demo
Via File → Open point to the file AnalogMAX_DAQ1_Capture.vac from the demo folder.
Click Browse... and select the file "adcapture.exe" from the downloaded demo.
Into Arguments insert "COMX,115200 1024 c:\temp\capture.txt 1", where the X in COMX
is a placeholder for your comport number.
COM14 - COM port which is used for the connection.
115200 - Baud rate which is used for the connection.
1024 - Amount of K samples to read, minimum 64 and maximum is 1024.
c:\temp\capture.txt - File name and path which specifies where to storage the data.
1 - Command to adjust for the modules gain, possible values are:
TEI0015 and TEI0016: 1 for a gain of 1, 2 for a gain of 2, 4 for a gain of 4 and 8 for a gain of 8
TEI0023: 1 for a gain of 0.25, 2 for a gain of 0.5, 3 for a gain of 1, 4 for a gain of 2, 5 for a gain of 4, 6 for a gain of 8 and 7 for a gain of 16
TEI0015 - 2 MHz / Resolution - 18 bit
TEI0016-0x-08-C8A - 0.5 MHz / Resolution - 16 bit
TEI0016-0x-08-C8B - 1 MHz / Resolution - 16 bit
TEI0023 - 2 MHz / Resolution - 18 bit
This sampling rate is only changed, when the demo has been run.
It is often necessary to fill in the value two times before it is recognized.
In dependency to the language settings, 0.5 MHz is sometimes not recognized,
try instead of the separation point (0.5) a separation comma (0,5) or without the zero (.5 ,5)
In the graph section, one can check the present sampling rate
the small Button, and adjust in the new appearing window the resolution.Quick test with a terminal program