Trenz Products


EOL of our module series is normally as long as Xilinx and Intel will offer the FPGA/SoC:

Passive components (resistors, capacitors) can be changed on the modules without notification. We use different manufacturer and best prices, but in any case the characteristics which are specified in the schematics are the same.

In case other active components will be not longer available, we will replace with footprint compatible equivalent alternatives or we update the PCB to support a equivalent alternatives variant. In case we change such a component, we will create also a new article number, so that you can directly see that something was be updated and we write a PCN



Trenz Electronic provides Module series with different assembly options (FPGA size, speed grade, temperature range, DDR size, QSPI size, eMMC size, less components, different stacking height...)
Identification can be done with the Article number and the corresponding Schematics in the download area of the modules. Module series name and PCB revision is directly printed on the module. Every module has also an unique serial (number on white sticker with QR code on the module), which can be used to identify the whole article number (and thus the assembly options).
Article number style has changed since 2019, so that you can identify main parts also with the article number encoding table:

Article Number Information



Xilinx device information can be requested with the 2D Bare code or Lot code on the device package.

This can be done via Xilinx App:

Or over web page:

In both cases a Xilinx login is needed.



Deviations from the general copyrights, if any, are indicated at the corresponding boards. If not the following applies:

Copyright for board with SoC/FPGA ( Modules / Motherboards...):

  • Project is protected under copyright and we strongly and strictly prohibit the reverse engineering or recreation, even if the design is just adapted or modified. is protected under such right and in case of plagiarism we will have to do anything necessary in order to protect our assets. Schematics and other handouts serve for informational purposes only!


Copyright for Carrier:

  • tbd



Downloads / Documents


You can lookup for file abbreviations on Documents Naming Conventions.



PCB document is available on our wiki pages and download area.



PCB Design


The maximum power consumption of a module manly depends on the design which is running on the FPGA.

Xilinx provide a power estimator excel sheets to calculate power consumption. It's also possible to generate power consumption of the developed design with Vivado.

Please also observe the TRM of the Trenz Electronic module and the power management of our corresponding carrier boards.



Module pinout files can be generated with our Master Excel Pinout Sheet. You can also use the schematic on our download area.



Trenz Electronic Modules which are offered in the shop are listed on our  shop page grouped by FPGA-Family. Wiki overview of the different series is available on Products



See Xilinx Answer Record: AR# 43989



Use in Altium, Design → "Create integrated library" It will recreate all used lib symbols



These connectors do not self align, so the placement has to be good initially. Connectors should be placed with 50µm accuracy. Not every assembly house can do this. However even with higher tolerances, the connection is normally stable.
We had one customer, who made a mistake in layout, offsetting one connector 125µm in x and 125µm in y. He still had connections, but noticed this only on the MGTs. They failed with high data rates.

Regarding Samtec Product specification: In Revision F of this document 7.1.1 Samtec defines max allowed misaligned 0.03mm, in Revision D it was 0.08mm. Also the recommendation (7.3) you are referring was not there when we designed and tested this B2B interface.
There is also a document describing general multiple connector applications:

Furthermore we discussed with Samtec and got following hints:

  • The Multiple Connector Applications document covers the processing and layout requirements as well as we can.  There are not any specific processing requirements for the SX5 components that are not covered in the document.
  • The customer should verify that they are following the recommended PCB and Stencil Layouts:  SS5, ST5.
  • We have seen in our trials with lead-free solder that the components will have a tendency to stay right where they are placed.  With a tin-lead soldering process, components are more likely to self-center.
  • We recommend .005” Stencil thickness.
  • If the components are not placed into the solder paste, but rather just sitting on top with no indentation of the paste, there could be more of a tendency to swim.
  • If it is known that the placement is ‘perfect’, issues with the reflow oven could be causing misalignment:  Vibration of the conveyor and/or imbalanced air flow from the convection fans.

As we saw the alignment issue with a few customers, we decided to make a sister series of TE0803, TE0807, TE0808 with other connectors.
These are: TE0813 / TE0817 / TE0818 with self aligning Samtec ADM6 B2B connectors
Samtec ADx have very good self alignment capabilities. We made tests with 6 connectors on one board, and there were no problems. The development of these boards is finished and the first boards will be produced in Q3 2021. If you have any reason for redesign anyway, you could consider using this series. We can sent you module footprint, if you want.



Vivado/SDK/SDSoC/PetaLinux


Reference Designs will be delivered as scripted project file. Vivado Project files will be generated with these scripts.

Windows and Linux (since Vivado 2016.4) start up command files are available to generate the project: Project Delivery QuickStart

All other options are described on: Vivado Projects - TE Reference Design



Trenz Electronic Board Part Files will be delivered with the reference designs on our download area.They ca be installed in different ways.

  1. Select the correct Board Part File: TE Board Part Files
  2. Install Board Part Files: Board Part Installation
  3. Use Board Part Files: Vivado Board Part Flow



Xilinx Documentation is available on Xilinx Hompage. Some helpful documentation and Links are available on  Xilinx Development Tools



 We provide PetaLinux template projects instead of BSPs for our modules. This template are included in our reference design in the subfolder (os/petalinux).

They are available on our download area. You can lookup for instructions on: PetaLinux KICKstart



 Xilinx provide a list with supported functionality and devices on: https://www.xilinx.com/products/design-tools/vivado/vivado-webpack.html



  1. Activate ES License with Xilinx License Manager
  2. Enable Beta Devices for Vivado
    1. open existing init.tcl (create new one if not exist) in one of this locations:
      1. C:/Xilinx/Vivado/<version>/scripts/
        or
      2. C:/Users/<user>/AppData/Roaming/Xilinx/Vivado/
    2. Add line:  enable_beta_device *

Now Vivado check all Beta Devices, but only Devices with valid license are visible. With Beta Device enable, Vivado need longer startup. Select special beta device is supported too.  See Xilinx Forum: Synthesis Failure for ZCU102



Insufficient external power supply can cause this issue. If power supply is insufficient, module restarts and FPGA content is erased. Vivado did not recognize this.



Please check following:
  1. Xilinx Programming Cable drivers are installed correctly
  2. "hw_server.exe" is terminated on task manage after all xilinx programs are closed. (if not kill this process or restart PC)
  3. Board Power Supply is sufficient and on
  4. JTAG USB Cable is connected to module and PC



Check if the Quad Enable (QE) bit in the Configuration Register of the flash is set to 1. If the QE-Bit is set or not depends on the last access to the flash.

  • This will be done automatically, when you configure Flash with Vivado or SDK and Flash in the design is specified as X4.
  • This will be not always done automatically, when you use other software to get access. For example Xilinx barmetal lib doesn't check if the QE bit is set or not.













Categories