Company | Trenz Electronic Gmbh |
---|---|
PCN Number | PCN-20150121 |
Title | TE0720 CPLD Revision upgrade 02 - 03 |
Subject | Trenz Electronic TE0720 SoM (system on module): CPLD Firmware upgrade to revision 03 |
Issue Date | 2015-01-21 |
This change affects all Trenz Electronic TE0720 SoMs of revision: TE0720-02-*.
Type: Enhancement
Reason: possible wrong bootmode latched under certain power up conditions
Impact: Bootmode is now latched with every Reset, not only at powerup.
All serial numbers starting with the following numbers will have CPLD Revision 03 or later.
Variant | Starting number |
---|---|
TE0720-02-1CF | 445958 |
TE0720-02-1CR | 445804 |
TE0720-02-1QF | 447873 |
TE0720-02-2EF | 445736 |
TE0720-02-2IF | 446790 444860-444865 |
It is possible to check the CPLD revision change on any base board or custom board where MODE pin value can be changed by switch or jumper. If the blink rate of the RED on module LED changes after changing the MODE pin setting and resetting the TE0720 (without power-down) then the CPLD revision is 03, if the blink rate (and boot mode) change requires powering off the module then the CPLD version is 02.
It is also possible to check the CPLD revision from u-boot by typing "mii read 0x1a 4" from u-boot prompt, the low order bits printed out as hex number are CPLD revision number.
TE0720-02 CPLD update can be done in-system on TE0703 baseboard or other carrier boards that support updating SC in-system.
https://wiki.trenz-electronic.de/display/TE0720/SC+Update
From 21.1.2015
If you have any questions related to this PCN, please contact Trenz Electronic's Technical Support at
phone
national calls: 05223 65301-0
international calls: 0049 5223 65301-0
Any projected dates in this PCN are based on the most current product information at the time this PCN is being
issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information,
please contact your local Trenz Electronic sales office, technical support or local distributor.