Download PDF Version of this Document.


Table of Contents

Overview

Refer to https://shop.trenz-electronic.de/de/Download/?path=Trenz_Electronic/PMOD/TEP0001 for online version of this manual and other documents available about the product.
 

The Trenz Electronic TEP0001 is an industrial-grade dual CAN FD transceiver with Pmod interface.

Features

Main Components

 

TEP0001 PMOD connector is mounted for Right Angle connection to PMOD Baseboard.

Interfaces and Pins

J1 Connector, CAN0 Bus

PinSignalNotes
1CAN0_HU1 high level CAN bus line
2GNDU1 ground connection
3CAN0_LU1 low level CAN bus line

J2 Connector, Pmod Interface

PinSignalNotes PinSignalNotes
1CAN0_TX

U1 CAN0 transmit data input,

integrated pull up

 2CAN1_TX

U2 CAN1 transmit data input,

integrated pull up

3CAN0_RX

U1 CAN0 receive data output, tri-state

 4CAN1_RX

U2 CAN1 receive data output, tri-state

5CAN0_S

U1 silent mode,integrated pull down

 6CAN1_S

U2 silent mode, integrated pull down

7CAN0_FU1 open drain fault output 8CAN1_FU2 open drain fault output
9GNDU1 ground connection 10GNDU2 ground connection
113.3VU1 3.3V supply voltage 123.3VU2 3.3V supply voltage

J3 Connector, CAN0 Bus

PinSignalNotes PinSignalNotes
1N/A- 2GNDU1 ground connection
3CAN0_LU1 low level CAN bus line 4CAN0_HU1 high level CAN bus line
5GNDU1 ground connection 6N/A-
7N/A- 8N/A-
9N/A- 10N/A-

J4 Connector, CAN1 Bus

PinSignalNotes PinSignalNotes
1N/A- 2GNDU2 ground connection
3CAN1_LU2 low level CAN bus line 4CAN1_HU2 high level CAN bus line
5GNDU2 ground connection 6N/A-
7N/A- 8N/A-
9N/A- 10N/A-

J5 Jumper Block/Connector CAN1 bus

Close pins 1-3 and 2-4 with jumpers to enable on-board terminator for CAN1 bus. J5 header can also be used as CAN1 bus connector, refer to the following table pin mapping.

PinSignalNote PinSignalNote
3CAN1_LU2 low level CAN bus line 4CAN1_HU2 high level CAN bus line
5GNDU2 ground connection 6GNDU2 ground connection

J6 Jumper Block/Connector, CAN0 bus

Close pins 1-3 and 2-4 with jumpers to enable on-board terminator for CAN0 bus. J6 header can also be used as CAN0 bus connector, refer to the following table for pin mapping.

PinSignalNote PinSignalNote
3CAN0_LU1 low level CAN bus line 4CAN0_HU1 high level CAN bus line
5GNDU1 ground connection 6GNDU1 ground connection

Operating Conditions, Ratings and Dimensions

Absolute Maximum Ratings

 ParameterMinimumMaximumUnit
Supply voltage range-0.35

V

Voltage at any bus terminal (CANH or CANL)-1414V
Operating temperature range-40150°C
Storage temperature-150°C

Recommended Operating Conditions

 MinimumMaximumUnit
Supply voltage33.6V
Operational free-air temperature-40125°C

Refer to Texas Instruments TCAN337G product datasheet for additional information about conditions and ratings.

Power Requirements

3.3V supply voltage TBD* (180 mA max per one CAN FD transceiver in "Normal Mode", dominant state with bus fault as per TCAN337G datasheet).

* TBD - To Be Determined soon with reference design setup.

Physical Dimensions

Revision History

Hardware Revision History

DateRevision

Notes

PCN
2016-08-22

01

Initial batch

 -

Hardware revision number is printed on the PCB board next to the module model number separated by the dash.

 

Document Change History

Date

Rrevision

Contributors

Description

2016-09-05
Initial document.

Disclaimer