This Trenz Electronic Starter Kit consists of a TE0808 module on a TEBF0808 base board in Mini-ITX Enclosure. See shop link for detailed content.
Do not change XMOD DIP-Switch settings on TEBF0808. Do not swap the XMOD adapters the one marked with green dot must be closer to the SoM |
ES devices are not included in all Vivado versions, for ES1 only: activate beta device see: FAQ - How can I activate beta devices? |
For all Starter Kit's shipped before 2017-06-21: Enclosure Power and HD LED was swapped on connector. See "Enclosure Power Button, Reset Button, HDD LED and Power LED" section for correct connection. |
Starter Kit is shipped with prebuilt Linux Example on SD. Newest version and sources are available on our download area: TE0808 Reference Designs
Connect main power and set power switch to on. See Main Power Enclosure Location
Do not change XMOD DIP-Switch settings on TEBF0808. Do not swap the XMOD adapters the one marked with green dot must be closer to the SoM |
TEBF0808 | TE0790-02 (with green dot) | TE0790-02L | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
Note: with CPLD Firmware REV06 or newer, S4.4 can be set to OFF, to save power, if Starter Kit is powered off with Power Button.
For more information, see:TEBF0808, TEBF0808 Master CPLD and TEBF0808 Slave CPLD.
- Section is currently not complete -
No Power on Starter Kit.
Identification: FANs do not work, all LEDs are off.
Only some basics on TEBF0808 are powered on. This mode is used for CPLDs Firmware updates.
Identification: FANs do not work, some LEDs blinking.
LED description(need CPLD Firmware REV06 or newer):
BLUE Power LED on enclosure | ||
---|---|---|
Status/ User | Blink Sequence | Comment |
Power | ******** (slow blink) | Indicate board is powered off. |
RGPIO controlled | User Defined | RGPIO 14 and 15, if RGPIO is active. |
MIO40 | User Defined | MIO40, if RGPIO is deactivated |
TE0808 will be powered on. System boots if boot mode is set correct and files are available.
Identification: FANs do work, LEDs blinking states change.
LED description (need CPLD Firmware REV06 or newer):
BLUE Power LED on enclosure | ||
---|---|---|
Status/ User | Blink Sequence | Comment |
Power | ******** (slow blink) | Indicate board is powered off. |
RGPIO controlled | User Defined | RGPIO 14 and 15, if RGPIO is active. |
MIO40 | User Defined | MIO40, if RGPIO is deactivated |
Red HD LED on enclosure | ||
---|---|---|
Status/ User | Blink Sequence | Comment |
PS_INIT_B | ******** | Indicates the PS is not initialized after a power-on reset (POR). |
PS_ERROR_OUT | *****ooo | The PS_ERROR_OUT signal is asserted for accidental loss of power, an error, or an exception in the PMU. |
ERR_STAT | ****oooo | The PS_ERROR_STATUS indicates a secure lockdown state. Alternatively, it can be used by the PMU firmware to indicate system status. |
RGPIO controlled | User Defined | RGPIO 16 and 17, if RGPIO is active |
SC0 | User Defined | SC0 (PL IO), if RGPIO is deactivated |
Most LEDs are CPLD Firmware dependents, see TEBF0808 Master CPLD and TEBF0808 Slave CPLD
Starter Kit will be shipped with all cable connected.