Download PDF Version of this Document. |
Company | Trenz Electronic GmbH |
---|---|
PCN Number | PCN-20160706 |
Title | TE0706-01 to TE00706-02 Hardware Revision Change |
Subject | Trenz Electronic TE0706 Hardware Change |
Issue Date | 20160706 |
This change affects all Trenz Electronic TE0706 Carriers of revision: TE0706-01*.
affected product | suggested upgrade |
---|---|
TE0706-01* | TE0706-02* |
Type: Layout change
Reason: Allow easier setting of IO Voltages
Impact: Voltage VCCIOA, VCCIOB, VCCIOC independent selectable (1,8V or 3.3V) via jumper J10, J11, J12. Boards are delivered now with default IO voltages of 1.8V. Check Jumper settings and change to your needs.
Type: BOM change
Reason: Improve manufacturing
Impact: None
Type: Layout change
Reason: Adapt to standard XMOD without special firmware.
Impact: XMOD with standard firmeware needed.
Type: SCH change
Reason: Possibility to disconnect CLK125 for compatibility with modules having GTs
Impact: None
Type: BOM change
Reason: Better mechanical stability
Impact: None
Type: BOM change
Reason: Improve Ethernet PHY power supply
Impact: None
Type: PCB change
Reason: Improve manufacturing
Impact: None
Type: BOM change
Reason: Allow automated identification of module
Impact: None
Type: Layout change
Reason: Better thermal performance
Impact: None
Type: BOM change
Reason: Cost saving
Impact: None
Type: BOM change
Reason: R22 on SD_CLK not needed
Impact: None
Type: SCH change
Reason: Improve power input protection
Impact: None
Type: SCH change
Reason: Prepare for future use.
Impact: None (PG now correct working, but currently not used)
Type: SCH change
Reason: Improve reliability with stronger pullup
Impact: None
Type: SCH change
Reason: Production homogenization
Impact: None
Type: SCH change
Reason: Cost saving
Impact: If VBAT is used a pin header has to be solderd
Type: BOM change
Reason: Production homogenization
Impact: None
The model code and revision number (e.g. TE0706-01 or TE0706-02) are printed on the top side of the PCB.
From August 2016, after REV 01 stock is gone.
If you have any questions related to this PCN, please contact Trenz Electronic's Technical Support at
phone
national calls: 05223 65301-0
international calls: 0049 5223 65301-0
Any projected dates in this PCN are based on the most current product information at the time this PCN is being
issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information,
please contact your local Trenz Electronic sales office, technical support or local distributor.