| Company | Trenz Electronic GmbH |
|---|---|
| PCN Number | PCN-20240229 |
| Title | TE0713-02 to TE0713-03 Hardware Revision Change |
| Subject | Hardware Revision Change |
| Issue Date | 2024-06-07 |
This change affects all Trenz Electronic TE0713 SoMs: TE0713-02*.
Affected Product | Replacement |
|---|---|
| TE0713-02-72C46-A | TE0713-03-72C46-A |
| TE0713-02-82C46-A | TE0713-03-82C46-A |
Type: Schematic Change
Reason: EOL of Component.
Impact: None. Minor changes in electrical characteristics.
Type: Schematic Change
Reason: BOM Optimization.
Impact: None. Minor changes in electrical characteristics.
Type: Schematic Change
Reason: BOM Optimization.
Impact: None. Increased current output capability. Minor changes in electrical characteristics.
Type: Schematic Change
Reason: Improve power monitoring.
Impact: Improved power monitoring circuit by supervising additional voltage rails. If monitored voltages are out of range signal "PG_SENSE" is triggered.
Type: Schematic Change
Reason: Improvement of DCDC handling.
Impact: None. I2C bus has additional device with I2C address 0x61.
Type: Schematic Change
Reason: Keep FPGA in reset while signal "PROG_B" is low during initial power-up.
Impact: None.
Type: Schematic Change
Reason: Setup PROGRAM_B_0 functionality externally.
Impact: None.
Type: Schematic Change
Reason: Follow AMD recommendation.
Impact: None.
Type: Schematic Change
Reason: Add external pull-up resistor for write protect functionality.
Impact: None. Improve usable flash options.
Type: Schematic Change
Reason: Improve clock termination.
Impact: None.
Type: Schematic Change
Reason: Disable 245 Synchronous FIFO Mode externally.
Impact: None.
Type: Schematic Change
Reason: Add 245 Synchronous FIFO Mode option.
Impact: None.
Type: Schematic Change
Reason: Add FT600Q GPIO0 setup option.
Impact: None.
Type: Schematic Change
Reason: Add FT600Q GPIO1 setup option.
Impact: None.
Type: Schematic Change
Reason: Follow FTDI recommendation.
Impact: None.
Type: Schematic Change
Reason: Follow AMD recommendation.
Impact: None.
Type: Schematic Change
Reason: Signal termination.
Impact: None.
Type: Schematic Change
Reason: Signal termination.
Impact: None.
Type: BOM Change
Reason: EOL of component.
Impact: None.
Type: Schematic Change
Reason: BOM Optimization.
Impact: None.
Type: Schematic Change
Reason: BOM Optimization.
Impact: None.
Type: Schematic Change
Reason: BOM Optimization.
Impact: None.
Type: Schematic Change
Reason: BOM Optimization.
Impact: None.
Type: Schematic Change
Reason: BOM optimization.
Impact: None.
Type: Schematic Change
Reason: BOM optimization.
Impact: None.
Type: Schematic Change
Reason: BOM optimization.
Impact: None.
Type: Schematic Change
Reason: Placement optimization.
Impact: None.
Type: Schematic Change
Reason: Voltage and system monitoring improvement.
Impact: None.
Type: Schematic Change
Reason: Update board revision identification.
Impact: None.
Type: Schematic Change
Reason: Use latest component data.
Impact: None.
Type: PCB change
Reason: Result of changes above.
Impact: Changed trace length have to be taken into account in existing designs. The trace length for new revision will be available in TE0713 series pinout generator. Please check if change in trace length still matches your requirements. Adaption of carrier may be necessary.
Type: Documentation Update
Reason: Documentation improvement.
Impact: None.
Type: Documentation Update
Reason: Documentation improvement.
Impact: None.
The revision number is shown on the top side of the PCB. Revision number position changes between REV02 and REV03 on top side of the PCB.
This change takes place with immediate effect. If the new revision is not suitable for your application and still the former revision of the board is needed, please contact us.
If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at
phone
national calls: 05741 3200-0
international calls: 0049 5741 3200-0
Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.
This PCN follows JEDEC Standard J-STD-046.