Company | Trenz Electronic GmbH |
---|---|
PCN Number | PCN-20231006 |
Title | TE0630-02 to TE0630-03 Hardware Revision Change |
Subject | Hardware Revision Change |
Issue Date | 2023-11-01 |
This change affects all Trenz Electronic TE0630 SoMs: TE0630-02*.
Affected Product | Replacement |
---|---|
TE0630-02I | TE0630-03-52I12-A |
TE0630-02IBF | TE0630-03-63I12-A |
TE0630-02IV | TE0630-03-82I12-A |
TE0630-02B-DWS | - |
TE0630-02IBFC1 | - |
TE0630-02IV-DWS | - |
TE0630-02-52C12-A | - |
Type: Schematic Change
Reason: EOL of Component.
Impact: None. Increased current output capability. Minor changes in electrical characteristics.
Type: Schematic Change
Reason: EOL of Component.
Impact: None. Minor changes in electrical characteristics.
Type: Schematic Change
Reason: Enable "HSWAPEN" pull-down option.
Impact: None.
Type: Schematic Change
Reason: New revision.
Impact: If hardware coding of board revision is used in design, update is needed.
Type: Schematic Change
Reason: New revision.
Impact: If hardware coding of board variant is used in design, update is needed.
Type: Schematic Change
Reason: Follow clock enable recommendation.
Impact: None.
Type: Schematic Change
Reason: Follow clock enable recommendation.
Impact: None.
Type: Schematic Change
Reason: Follow AMD recommendation.
Impact: None.
Type: Schematic Change
Reason: BOM Optimization.
Impact: None.
Type: Schematic Change
Reason: BOM Optimization.
Impact: None.
Type: Schematic Change
Reason: EOL of Component.
Impact: None.
Type: Schematic Change
Reason: Use standard fiducials.
Impact: None.
Type: Schematic Change
Reason: Testpoints not needed.
Impact: None.
Type: Schematic Change
Reason: Improve signal integrity.
Impact: None.
Type: Schematic Change
Reason: Optimize signal monitoring.
Impact: None.
Type: PCB Change
Reason: Required for export to UK.
Impact: None.
Type: Schematic Change
Reason: Result of changes above.
Impact: None.
Type: Schematic Change
Reason: Use latest component data.
Impact: None.
Type: Documentation Update
Reason: Documentation improvement.
Impact: None.
Type: Documentation Update
Reason: Documentation improvement.
Impact: None.
The revision number is shown on the top side of the PCB. Revision number position changes between REV02 and REV03 on top side of the PCB.
From May 2024, after old stock is gone. If the new revision is not suitable for your application and still the former revision of the board is needed, please contact us.
If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at
phone
national calls: 05741 3200-0
international calls: 0049 5741 3200-0
Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.
This PCN follows JEDEC Standard J-STD-046.