Company | Trenz Electronic GmbH |
---|---|
PCN Number | PCN-20201026 |
Title | TEC0330-04 to TEC0330-05 Hardware Revision Change |
Subject | Hardware Revision Change |
Issue Date | 2020-10-27 |
This change affects all Trenz Electronic TEC0330 modules of revision 04.
Affected Product | Replacement |
---|---|
TEC0330-04 | TEC0330-05 |
Type: BOM change
Reason: Old fan is end of life.
Impact: Specified airflow of fan decreases slightly from 0.03 m³/min to 0.028 m³/min.
Type: Schematic change
Reason: Xilinx recommendation for GTH transeivers reference clocks (UG476).
Impact: AC coupling according to datasheet.
Type: Schematic change
Reason: Reflect actual hardware revison.
Impact: If hardware board revision bits are used, the design has to be updated accordingly.
The revision number is printed on the top side of the PCB.
From February 2021, after old stock is gone. If still the old assembly variant is needed please contact us.
If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at
phone
national calls: 05741 3200-0
international calls: +49 5741 3200-0
Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.
This PCN follows JEDEC Standard J-STD-046.